| Plan Review Notes For Permit 22050777 |
| Permit Number |
22050777 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-09-29 15:42:37 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC R 301.2.1.4.3, THE EXPOSURE CATEGORY IN THE | | | ENGINEER'S LETTER IS "C" BUT ACCORDING TO THIS SECTION | | | OF THE FLORIDA BUILDING CODE, THIS LOCATION APPEARS TO | | | FALL UNDER EXPOSURE CATEGORY "D". PLEASE CORRECT THE | | | EXPOSURE CATEGORY AND EVALUATE/SHOW THAT THE WIND/WIND | | | LOAD PRESSURES MEET THE CODE REQUIREMENTS. | | | | | | |
|