2023-01-04 15:56:02RESIDENTIAL (R3) ALTERATION, FOURTH BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22050716
 1222 ALPHA ST
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT
 NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW.
  
 1- REVISE ENERGY CALCULATIONS:
  
 A)OK.
  
 PREVIOUS COMMENT:
 B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. OWNER'S NAME IS INCORRECT. NEED BUILDER'S NAME,
 PERMIT OFFICE AND JURISDICTION (THIS IS 604700
 JURISDICTION). SEC. R101.5.1.1.2 FBC-RESIDENTIAL.
  
 RESPONSE:
 MISSING THE PERMIT OFFICE AND JURISDICTION NUMBER
 (604700). ALSO, CORRECT ZIP CODE IS 33401 NOT 33304.
 REVISE AS REQUIRED.
  
 C)OK.
 D)OK.
 E)OK.
  
 PREVIOUS COMMENT:
 F)CEILING INSULATION SPECIFIED ON ITEM #11 DOESN'T
 MATCH PLANS. REVISE AS REQUIRED. ALSO, THE CEILING OF
 THIS STRUCTURE IS NOT FLAT. SEE PLANS AND REVISE AS
 REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL.
  
 RESPONSE:
 THIS ITEM HAS TO BE COORDINATED WITH ITEM #2 BELOW.
 PLANS NEED TO BE REVISED.
  
 PREVIOUS COMMENT:
 G)ITEM #11 SPECIFY VENTED CEILING. PROVIDE DETAILS AND
 SPECIFICATIONS SHOWING HOW THE CROSS VENTILATION IS
 PROVIDED. PLANS DON'T SHOW THIS. ROOF NEEDS CROSS
 VENTILATION AS REQUIRED BY SEC. R806.1 FBC-RESIDENTIAL.
 R-19 BATT INSULATION DOESN'T FIT ON 2X6 ROOF JOISTS. IT
 DOESN'T ALLOW ROOF CROSS VENTILATION. SEC. R806.3
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 RESPONSE:
 ENERGY CALCULATIONS STILL SHOW VENTED ATTIC. PLANS
 DON'T SHOW ANY ATTIC CROSS VENTILATION. COORDINATE WITH
 ITEM # 2 BELOW.
  
 H)OK.
  
 PREVIOUS COMMENT:
 I)PROVIDE THE NAME OF THE PERSON DOING THE CALCULATIONS
 AS REQUIRED BY SEC. R405.4.2.1 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT.
  
 J)OK.
  
 PREVIOUS COMMENT:
 K)ROOF TYPE SPECIFIED ON PAGE 2 DOESN'T MATCH PLANS.
 REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT.
  
 L)OK.
 M)OK.
 N(OK.
  
 NEW COMMENTS BASED ON REVISED ENERGY CALCULATIONS:
  
 2- IT IS NOT CLEAR IF ENGINEER OF RECORD IS DESIGNING A
 VENTED OR UNVENTED ATTIC. ENERGY CALCULATIONS SPECIFY
 VENTED ATTIC BUT PLANS DON'T SHOW VENT INFORMATION.
 ENGINEER TO READ SEC. R806 BC-RESIDENTIAL
 AND PROVIDE COMPLETE INFORMATION ON PLANS SHOWING
 COMPLIANCE WITH ATTIC CROSS VENTILATION SEC. R806.2
 FBC-RESIDENTIAL OR ENGINEER TO PROVIDE COMPLETE
 INFORMATION ON PLANS SHOWING COMPLIANCE WITH UNVENTED
 ATTIC SEC. R806.5 FBC-RESIDENTIAL. ENGINEER TO SPECIFY
 TYPE OF INSULATION AND R-VALUE.
 NOTE: IF USING BATT INSULATION, 2X6 ROOF RAFTERS DON'T
 HAVE ENOUGH ROOM TO ALLOW INSULATION CLEARANCE FOR
 CROSS VENTILATION (SEE SEC. R806.3 FBC-RESIDENTIAL).
 TYPICALLY SPRAY FOAM INSULATION (LIKE ICYNENE) IS USED
 FOR UNVENTED ATTICS. IF ENGINEER IS DESIGNING UNVENTED
 ATTIC THEN PROVIDE ICC EVALUATION REPORT FOR THE
 ICYNENE INSULATION (OR ANY OTHER ONE SPECIFIED BY THE
 ENGINEER) TO VERIFY COMPLIANCE WITH SEC. R316
 FBC-RESIDENTIAL (NOTE: ENGINEER TO REVIEW AND APPROVE
 THE REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS
 OFFICE).
  
 3- ENERGY CALCULATIONS WERE REVISED FOR WORST CASE
 SCENARIO. THIS IS NOT ALLOWED. ENERGY CALCULATIONS NEED
 TO BE SITE SPECIFIC AS REQUIRED BY SEC. R405.4.2.1 (4)
 FBC- ENERGY CONSERVATION. REVISE AS REQUIRED.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  