| Date |
Text |
| 2022-05-16 17:08:20 | 1ST REVIEW FBC-2020 RES. PLUMBING |
| | PERMIT- 22050548 |
| | 5/16/2022 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET A.2: THE PERMIT APPLICATION INDICATES GARAGE |
| | CONVERSION HOWEVER THE PLAN INDICATES GUEST HOUSE |
| | REMODELING. PLEASE CLARIFY THE SCOPE OF WORK FOR THE |
| | PROJECT- SEC. 107.2.1 WPB. ARE THE PLUMBING FIXTURES |
| | NEW INSTALLATIONS OR REPLACEMENT OF EXISITNG? |
| | |
| | |
| | 2) A.2: PROVIDE A RISER DRAWING FOR ALL NEW SANITARY |
| | DRAINAGE AND VENT PIPE INSTALLATIONS- SEC. 107.3.5.3 |
| | WPB. |
| | |
| | 3) NOTE: TWO DWELLINGS ON THE SAME, OR CONSTRUCTION OF |
| | A COMMERCIAL BUILDING ON THE PROPERTY WILL REQUIRE |
| | INSTALLATION OF A POTABLE WATER SERVICE BACKFLOW |
| | PREVENTER DEVICE IN ACCORDANCE WITH THE WPB DEPT. OF |
| | UTILITIES CROSS-CONNECTION CONTROL MANUAL. PLEASE NOTE |
| | A SEPARATE PERMIT WILL BE REQUIRED TO INSTALL A REDUCED |
| | PRESSURE ZONE (RPZ) BACKFLOW AT THE WATER METER- SECS. |
| | C & E WPB CROSS-CONNECTION MANUAL. |
| | |
| | A FL. LICENSED PLUMBING CONTRACTOR SHALL OBTAIN A |
| | SEPARATE PERMIT FOR INSTALLATION OF THE BACKFLOW |
| | PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB AND SEC. |
| | 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL BE |
| | TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT |
| | PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT. |
| | PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS |
| | DEPT.AT 561-822-2210 FOR FURTHER INFORMATION. |
| | |
| | DUE TO A CHANGE IN PROCESS, THE BACKFLOW PERMIT IS |
| | REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF THE |
| | PRIMARY PERMIT (AS APPLICABLE). YOU CAN SUBMIT AN |
| | APPLICATION ?TBD? (TO BE DETERMINED) IF YOU DO NOT HAVE |
| | A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT |
| | APPLICATION TO [email protected] . YOU WILL |
| | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU |
| | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE |
| | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT |
| | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER |
| | YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL |
| | AND I WILL CHANGE THE REVIEW STATUS TO PASS. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |