| Plan Review Notes For Permit 22050315 |
| Permit Number |
22050315 |
|
| Review Stop |
B |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2022-10-07 10:36:53 | ENCLOSE CARPORT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | | | | 1) YOU PROVIDED A PRODUCT APPROVAL FOR A SLIDING GLASS | | | DOOR - THE DRAWINGS DO NOT SHOW A LOCATION FOR THE | | | SLIDING GLASS DOOR. | | | | | | 2) PRODUCT APPROVAL - NOA 20-0722.10 FOR THE SINGLE | | | HUNG WINDOW IS RATED FOR SMALL MISSILE IMPACT ONLY - | | | WHICH MEANS WHEN INSTALLED BELOW 30 FEET FROM GRADE A | | | SHUTTER IS REQUIRED - PLEASE PROVIDE THE PRODUCT | | | APPROVAL FOR THE REQUIRED SHUTTERS. FBC R301.2.1.2 |
|