| Date |
Text |
| 2022-06-25 12:16:23 | PETER E VALENTI |
| | BUILDING PLANS EXAMINER II |
| | [email protected] |
| | 561 805 6673 |
| | |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC M = FBC MECHANICAL |
| | FBC FG = FBC FUEL GAS |
| | |
| | BUILDING REVIEW DENIED: |
| | |
| | 1.) FBC B 107.2.6, PROVIDE A SITE-PLAN THAT INCLUDES, |
| | FOR PROPOSED NEW WORK, DISTANCES TO LOT LINES. |
| | 2.) FBC B 107.2.1, PROVIDE CLARITY FOR THE FOOTING |
| | DETAILS THAT ARE TO BE USED AT EACH LOCATION. FOR |
| | EXAMPLE, IT IS NOT CLEAR AS TO WHICH FOOTING WILL BE |
| | USED AT THE NEW FRONT "PORTICO" AREA. |
| | 3.) FBC B 107.2.1, PROVIDE DETAILS FOR THE FRONT |
| | COLUMNS OF THE PORTICO. |
| | 4.) FBC B 107.2.1, PLEASE CLARIFY OR PROVIDE WHAT |
| | APPEARS TO BE MISSING STRUCTURAL PLAN SHEETS AS PLAN |
| | SHEET A-2 HAS REFERENCING "SLAB EDGE DETAILS" |
| | IDENTIFIED AS A/S-1 & B/S-1. |
| | 5.) FBC B 107.2.1, PROVIDE OPENING IDENTIFICATION |
| | NUMBERS ON PROPOSED FLOOR PLAN AND ELEVATION SHEETS TO |
| | MATCH WITH THE PRODUCT APPROVAL SCHEDULE SHOWN ON PLAN |
| | SHEET A-1. |
| | 6.) FBC R 905.1.1.1, PROVIDE THE METHOD OF ROOFING |
| | UNDERLAYMENT FOR SHINGLES ( SELF ADHERING BITUMEN |
| | UNDERLAYMENT, 4" WIDE STRIPS, FLASHING TAPE, OR |
| | 2-LAYERS OF FELT) THAT WILL MEET THE CODE REQUIREMENTS |
| | IN ADDITION TO THE FELT PAPER THAT IS NOTED UNDER THE |
| | ROOFING ASSEMBLY DETAILS ON PLAN SHEET A-14. |
| | 7.) FBC B 107.2.1/FBC B 107.3.4.1, SUBMIT ALL OF THE |
| | PRODUCT APPROVALS(WITH ENGINEER OF RECORD REVIEW STAMP) |
| | TO BE USED INCLUDING ALL ROOFING MATERIALS. IF THE |
| | PRODUCT APPROVALS ARE TO BE DEFERRED, PLEASE INCLUDE |
| | ALL ON PLAN SHEET. |