| Plan Review Notes For Permit 22050130 |
| Permit Number |
22050130 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-05-06 10:12:45 | FIRE PROVISO: | | | | | | 30.3.4.5* SMOKE ALARMS. SMOKE ALARMS SHALL BE INSTALLED | | | IN ACCOR DANCE WITH 9.6.2.10 IN EVERY SLEEPING AREA, | | | OUTSIDE EVERY SLEEPING AREA | | | IN THE IMMEDIATE VICINITY OF THE BEDROOMS, AND ON ALL | | | LEVELS OF THE | | | DWELLING UNIT, INCLUDING BASEMENTS. | | | | | | 9.6.2.10.1 WHERE REQUIRED BY ANOTHER SECTION OF THIS | | | CODE, SINGLE STATION AND MULTIPLE-STATION SMOKE ALARMS | | | SHALL BE IN ACCORDANCE WITH | | | NFPA 72 UNLESS OTHERWISE PROVIDED IN 9.6.2.10.3, | | | 9.6.2.10.4, 9.6.2.10.6, | | | OR 9.6.2.10.7 | | | | | | 9.6.2.10.3* THE INTERCONNECTION OF SMOKE ALARMS SHALL | | | APPLY ONLY TO | | | NEW CONSTRUCTION AS PROVIDED IN 9.6.2.10.9 | | | | | | 9.6.2.10.9* IN NEW CONSTRUCTION, WHERE TWO OR MORE | | | SMOKE ALARMS ARE | | | REQUIRED WITHIN A DWELLING UNIT, SUITE OF ROOMS, OR | | | SIMILAR AREA, THEY | | | SHALL BE ARRANGED SO THAT OPERATION OF ANY SMOKE ALARM | | | SHALL CAUSE THE | | | ALARM IN ALL SMOKE ALARMS WITHIN THE DWELLING UNIT, | | | SUITE OF ROOMS, OR | | | SIMILAR AREA TO SOUND, UNLESS OTHERWISE PERMITTED BY | | | ONE OF THE | | | FOLLOWING: | | | (1) THE REQUIREMENT OF 9.6.2.10.9 SHALL NOT APPLY WHERE | | | PERMITTED BY | | | ANOTHER SECTION OF THIS CODE. | | | (2) THE REQUIREMENT OF 9.6.2.10.9 SHALL NOT APPLY TO | | | CONFIGURATIONS | | | THAT PROVIDE EQUIVALENT DISTRIBUTION OF THE ALARM | | | SIGNAL | | | | | | PLEASE ENSURE COMPLIANCE | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | |
|