Plan Review Notes
Plan Review Notes For Permit 22041433
Permit Number 22041433
Review Stop NFIP
Sequence Number 2
Notes
Date Text
2022-06-07 17:20:00NFIP PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: DUE TO AN ERROR DISCOVERED DURING THE
 PROCESSING OF THIS ELEVATION CERTIFICATE (EC), A NEW
 FINISHED CONSTRUCTION EC IS REQUIRED.
  
 1. LINE C2 (E) REQUIRES THE LOWEST ELEVATION OF
 MACHINERY OR EQUIPMENT SERVICING THE BUILDING.
 AN ELEVATION OF 11.0 FEET NAVD WAS ENETERED FOR LINE C2
 (E).
 IN SECTION D, COMMENTS, IT WAS STATED THAT THIS
 ELEVATION WAS THE ELEVATOR PIT.
 THE ELEVATOR PIT IS A FLOOR, NOT MACHINERY OR
 EQUIPMENT.
 PLEASE IDENTIFY THE ELEVATION AND LOCATION OF THE
 LOWEST MACHINERY OR EQUIPMENT SERVICING THE BUILDING
 AND RE-SUBMIT THE FINISHED CONSTRUCTION EC.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  
  