| Date |
Text |
| 2023-07-03 13:23:03 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2020 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 22041189 |
| | ADD: 2032 N DIXIE HWY. |
| | CONT: SOLID ROCK RENOVATION |
| | TEL: 561-577-3057 |
| | E-MAIL: [email protected] |
| | |
| | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 3RD REVIEW |
| | DATE: TUES. 7-03-23 |
| | ACTION: DENIED |
| | 1-4) COMPLIED, WINDOW & DOOR PERMIT 23030707. 2020 |
| | FBC-B 1603.1.4 WIND DESIGN CRITERIA. |
| | |
| | 5) SHEET COVERSHEET. SCOPE OF WORK, COMMENTS: |
| | |
| | 5A) 3RD REQUEST. SEMI-COMPLIED, NOTE # 2 INDICATES NEW |
| | VINYL FLOORING, PLEASE DESIGNATE THE LOCATIONS OF |
| | FLOORING REQUIRING UNDERLAYMENT IN THE 2ND STORY |
| | RESIDENTIAL UNITS AND MAIN CORRIDOR AND OVER THE 1ST |
| | FLOOR RESIDENTIAL OCCUPANCIES. 2020 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION 107.2.1. |
| | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN |
| | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| | SPECIFIC TO THE TECHNICAL CODES. A WRITTEN ANALYSIS |
| | NEEDS TO ACCOMPANY THE PLANS AS TO HOW YOU ARE GOING TO |
| | ACHIEVE BOTH AN IIC & STC RATING OF 50 OR MORE. THE |
| | SHEET A-3 SHOWS A FLOOR CEILING ASSEMBLY GA FILE FC5250 |
| | THAT SHOW A STC RATING OF 45 TO 49 DB RATING. THE SAME |
| | HOLDS TRUE FOR THE WALL RATING BETWEEN THE R2 TENANT |
| | SPACES FOR BOTH THE 1ST FLOOR UNITS AND WALL RATING FOR |
| | THE 2ND FLOOR R2 OCCUPANCIES BOTH FLOOR SYSTEM AND WALL |
| | SYSTEMS NEED TO ACHIEVE A MINIMUM OF 50 DB FOR IIC & |
| | STC RATINGS. SEE COMMENTS 5A & 5B. |
| | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, |
| | STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND |
| | WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND |
| | UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING |
| | STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH |
| | OF THE STANDARDS FOR A WOOD FLOOR JOIST SYSTEM 6-INCH |
| | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: |
| | PLEASE PROVIDE ALL THREE TEST REPORTS FOR BUILDINGS |
| | SHOWING COMPLIANCE WITH: |
| | |
| | 5A)(1) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND. |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. |
| | |
| | 5B)(2) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, |
| | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING |
| | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR |
| | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS |
| | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR |
| | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E |
| | 90. |
| | |
| | 5C)(3) COMPLIED 1 HOUR FIRE RATING ASSEMBLY FOR |
| | FLOORING AND WALL ASSEMBLIES. |
| | 5B) COMPLIED, GA ASSOCIATION 1 HOUR FIRE RATING |
| | ASSEMBLIES FOR WALLS AND FLOORS. |
| | |
| | 5B)(1) COMPLIED, GA ASSOCIATION 1 HOUR FIRE RATING |
| | ASSEMBLIES FOR WALLS AND FLOORS. |
| | |
| | 5B)(2) 3RD REQUEST. SEE COMMENT 5A. BETWEEN DWELLING |
| | UNITS. FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, |
| | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING |
| | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR |
| | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS |
| | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR |
| | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E |
| | 90. |
| | |
| | 6) COMPLIED. |
| | |
| | 7) SEMI-COMPLIED, THE CONTRACTOR HAS SUBMITTED WHERE |
| | THEY WILL MEET THEIR DISPROPORTIONATE COST IN THE 1ST |
| | FLOOR RESTROOM. 2ND REQUEST PROVIDE LETTER ON EITHER |
| | THE DESIGN PROFESSIONAL OR CONTRACTOR LETTER HEAD WHERE |
| | THESE FUNDS ARE TO BE SPENT. FIRST FLOOR. FLORIDA |
| | ACCESSIBILITY CODE SECTION: DISPROPORTIONATE COST |
| | 202.4.1. PLEASE REVIEW HOW YOU ARE TO MEET |
| | DISPROPORTIONATE COST. EITHER THE CONTRACTOR OR THE |
| | DESIGNER OF RECORD ON THEIR LETTERHEAD NEED TO SHOW HOW |
| | THEY ARE GOING TO SPEND UP TO THE 20% DISPROPORTIONATE |
| | FUNDS LISTED FOR EACH ELEMENT WHERE THE FUNDS ARE BEING |
| | SPENT AND IN THE ORDER LISTED IN SECTION 202.4.1 |
| | DISPROPORTIONATE COST OF THE 2020 ACCESSIBILITY CODE. |
| | SHEET A-2 STILL MISSING ACCESSIBLE ELEMENTS IN THE |
| | ELEVATION VIEWS: |
| | A) CLEAR FLOOR SPACE DIAGRAM & DIMENSIONS FOR THE WATER |
| | CLOSET. SECTION 604.3 |
| | B) CLEAR FLOOR SPACE DIAGRAM & DIMENSIONS FOR THE |
| | LAVATORIES. SECTION 606.2. |
| | C) TURNING SPACE DIAMETERS. SECTION 304.3 |
| | D) TOILET FLUSH CONTROL SECTION 604.6 FLUSH CONTROLS TO |
| | BE LOCATED OPEN SIDE OF WATER CLOSET. |
| | E) CENTERLINES OF THE TOILET DISPENSER MEASURED FROM |
| | THE FRONTS OF THE WATER CLOSET. SECTION & FIGURE 604.7 |
| | F) HEIGHT OF THE MIRRORS FROM THE FINISHED FLOORS TO |
| | THE BOTTOM EDGE OF THE REFLECTIVE SURFACE, MIRRORS |
| | ABOVE SINKS. SECTION 606.3. |
| | 202.4.1. DISPROPORTIONATE COST. ALTERATIONS MADE TO |
| | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED |
| | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL |
| | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE |
| | ALTERATION TO THE PRIMARY FUNCTION AREA. COST THAT MAY |
| | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN |
| | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COST |
| | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN |
| | ACCESSIBLE ROUT TO THE ALTERED AREA; (II) COST |
| | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS |
| | ENLARGING DOOR OPENINGS, INSTALLING GRAB BARS, |
| | ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COST |
| | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| | TELEPHONE (TTY); (IV) COST ASSOCIATED WITH RELOCATING |
| | AN ACCESSIBLE DRINKING FOUNTAIN. |
| | |
| | 8) COMPLIED. |
| | |
| | 9) A NEW ARCHITECTURAL CANOPY HAS BEEN SUBMITTED, THERE |
| | IS NO LOCATION WHERE THIS IS TO BE INSTALLED, NO |
| | ENGINEERING SHEET NOR WIND LOAD OR FASTENING |
| | SCHEDULENOR HEIGHT OF THE BOTTOM OF CANOPY ABOVE |
| | GROUND, PROVIDE A SURVEY WITH LOCATION SHOWN ON THE |
| | SURVEY A SEPARATE PERMIT IS REQUIRED, PROVIDE VALUE FOR |
| | CANOPY. . 2020 WEST PALM BEACH AMENDMENTS TO THE |
| | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION |
| | 107.2.1. CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT |
| | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED |
| | BY THE BUILDING OFFICIAL. |
| | |
| | 10) A TRANSMITTAL LETTER / NARRATIVE LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| | REVIEW CYCLE. |
| | |
| | |
| | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| | PART-TIME/ SEMI-RETIRED. |
| | |
| | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| | BACK INTO THE OFFICE CALL |
| | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| | THANK YOU. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |