| Plan Review Notes For Permit 22040942 |
| Permit Number |
22040942 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-07-05 16:08:21 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE MORE CLARITY ON THE | | | SKETCH. THE SKETCH SUBMITTED IS MISSING THE FOOTING | | | DETAILS, DESIGN WINDLOAD SPECIFICATIONS, WALL AND | | | FRAMING CONNECTION DETAILS. ALSO, THE SKETCH IS MISSING | | | THE CREATOR OF THE SKETCHES SIGNATURE, SUCH AS GENERAL | | | CONTRACTOR. | | | | | | FBC B 107.2.1, PROVIDE DETAILS FOR THE CANVAS/COVERING | | | TO BE USED. THIS INFORMATION MUST INCLUDE THE MAXIMUM | | | WINDLOAD SPECIFICATIONS AND THE NOTICE AS TO WHAT | | | WINDSPEED THE COVERING MUST BE REMOVED. | | | | | | FBC B 107.2.6, PROVIDE A SURVEY AND SITE-PLAN SHOWING | | | THE PROPOSED LOCATION OF AWNING AND ALL SET-BACK | | | MEASUREMENTS. |
|