| Plan Review Notes For Permit 22040599 |
| Permit Number |
22040599 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-05-04 16:51:23 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22040599 | | | 5/4/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P.1 & P.2: THE 3-INCH WASHING MACHINE FIXTURE | | | DRAIN PIPES SHALL NOT BE REDUCED IN SIZE TO 2-INCH- | | | SEC. P3005.1.6 FBC RES. | | | | | | 2) P.1 & P.2: THE OUTDOOR SHOWER DRAIN WHICH WILL BE | | | OPEN TO RAIN AND FLOOD WATERS SHALL NOT DISCHARGE INTO | | | THE SANITARY- SEC. 90-126(B)(5) WPB CODE OR ORDINANCES, | | | AND SEC. R322.1.7 FBC RES. | | | | | | 3) REFER TO SEC. R322.1.6 FBC RES. AND PLACE NOTES OR | | | DETAILS ON THE PLAN TO INDICATE THE WATER HEATERS, HOSE | | | BIBS, SHOWER VALVE ARE INSTALLED AT OR ABOVE FLOOD | | | ELEVATION HEIGHT UNLESS MEETING THE EXCEPTION UNDER | | | R322.1.6. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|