| Date |
Text |
| 2023-02-13 10:41:47 | 2ND REVIEW FBC-2020 RES. GAS |
| | PERMIT- 22040597 |
| | 2/13/23 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. FAILED 1ST REVIEW COMMENTS |
| | ARE LISTED BELOW WITH ADDITIONAL NOTES. PLEASE CONTACT |
| | ME IF YOU HAVE QUESTIONS. |
| | |
| | 1) GAS RISER: ADDITIONAL INFORMATION REQUIRED ON THE |
| | DRAWING- CHAPTER 24 FBC RES. |
| | |
| | A) SHOW THE GAS SYSTEM PRESSURE- 2 PSI OR LOW |
| | PRESSURE.. |
| | B) SHOW A REGULATOR AND SHUT OFF VALVE AT WATER HEATER. |
| | C) SHOW THE TYPE AND SIZE OF MAIN SUPPLY PIPE FROM THE |
| | METER TO THE PE RISER. |
| | D) SHOW THE TYPE AND SIZE OF SUPPLY PIPE FROM THE |
| | REGULATOR AT THE POOL HEATER TO THE HEATER. |
| | E) SHOW PIPE CONNECTION AT THE METER TO EXISTING |
| | APPLIANCES AND PROVIDE THE TOTAL BTU LOAD OF THE |
| | EXISTING APPLIANCES AND THE NEW POOL HEATER. |
| | |
| | 2) PROVIDE A BASIC SITE PLAN THAT SHOWS THE LOCATIONS |
| | OF THE METER, POOL HEATER, AND UNDERGROUND PIPING RUN- |
| | SEC. 107.2.1 WPB. PLEASE INCLUDE THE INSTALLATION |
| | CLEARANCES FOR THE POOL HEATER- MINIMUM 4FT. FROM |
| | OPENINGS INTO THE BUILDING- SEC. G2427.8 FBC RES. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |