| Date |
Text |
| 2022-06-23 11:19:15 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC SEVENTH EDITION (2020) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE SITE SHOWN ON THE COVER SHEET PL0.00 IS NOT THE |
| | LOCATION OF THIS PROJECT. THIS PROJECT IS LOCATED AT |
| | 4334 N. FLAGLER DRIVE, WEST PALM BEACH, FLORIDA, FBC |
| | AMENDMENTS 107.2.1 |
| | |
| | 2) SUBMIT A COPY OF THE MANUFACTURER'S SPECIFICATIONS |
| | AND INSTALLATION INSTRUCTIONS FOR THE ADA POOL LIFT. |
| | FBC 107.2.1 |
| | |
| | 3) POOL IS SHOWN WITH A WATER DEPTH OF LESS THAN 4 |
| | FEET. FBC 454.1.2.2.4 POOL DEPTHS. THE MINIMUM WATER |
| | DEPTH SHALL BE 3 FEET (914 MM) IN SHALLOW AREAS AND 4 |
| | FEET (1219 MM) IN DEEP AREAS. |
| | |
| | 4) SHOW THAT THERE IS ADEQUATE CLEARANCE AT THE POOL |
| | LIFT. FBC 454.1.2.5.6 DISABLED ACCESS. PERMANENT OR |
| | PORTABLE STEPS, RAMPS, HANDRAILS, LIFTS OR OTHER |
| | DEVICES DESIGNED TO ACCOMMODATE HANDICAPPED INDIVIDUALS |
| | IN SWIMMING POOLS MAY BE PROVIDED. LIFTS MOUNTED INTO |
| | THE POOL DECK SHALL HAVE A MINIMUM 4-FOOT-WIDE (1219 |
| | MM) DECK BEHIND THE LIFT MOUNT. |
| | |
| | 5) SHOW COMPLIANCE WITH FBC 454.1.3.1.3. POOL WET DECKS |
| | SHALL HAVE A MINIMUM UNOBSTRUCTED WIDTH OF 4 FEET (1219 |
| | MM) AROUND THE PERIMETER OF THE POOL, POOL CURB, |
| | LADDERS, HANDRAILS, DIVING BOARDS, DIVING TOWERS AND |
| | SLIDES. |
| | |
| | 6) SHOW COMPLIANCE WITH FBC 454.1.3.1.5. WALKWAYS SHALL |
| | BE PROVIDED BETWEEN THE POOL AND THE SANITARY |
| | FACILITIES, AND SHALL BE CONSTRUCTED OF CONCRETE OR |
| | OTHER NONABSORBENT MATERIAL HAVING A SMOOTH |
| | SLIP-RESISTANT FINISH FOR THE FIRST 15 FEET (4572 MM) |
| | OF THE WALKWAY MEASURED FROM THE NEAREST POOL WATER'S |
| | EDGE. A HOSE BIBB WITH A VACUUM BREAKER SHALL BE |
| | PROVIDED TO ALLOW THE DECK TO BE WASHED DOWN WITH |
| | POTABLE WATER. |
| | |
| | 7) SHOW COMPLIANCE WITH FBC 454.1.6.1 SANITARY |
| | FACILITIES. SWIMMING POOLS WITH A BATHING LOAD OF 20 |
| | PERSONS OR LESS MAY UTILIZE A UNISEX RESTROOM. POOLS |
| | WITH BATHING LOADS OF 40 PERSONS OR LESS MAY UTILIZE |
| | TWO UNISEX RESTROOMS OR MEET THE REQUIREMENTS OF TABLE |
| | 454.1.6.1. UNISEX RESTROOMS SHALL MEET ALL THE |
| | REQUIREMENTS FOR MATERIALS, DRAINAGE AND SIGNAGE AS |
| | INDICATED IN SECTIONS 454.1.6.1.1 THROUGH 454.1.6.1.4. |
| | EACH SHALL INCLUDE A WATER CLOSET, A DIAPER CHANGE |
| | TABLE, A URINAL AND A LAVATORY. POOLS WITH A BATHING |
| | LOAD LARGER THAN 40 PERSONS SHALL PROVIDE SEPARATE |
| | SANITARY FACILITIES LABELED FOR EACH SEX. THE ENTRY |
| | DOORS OF ALL RESTROOMS SHALL BE LOCATED WITHIN A |
| | 200-FOOT (60 960 MM) WALKING DISTANCE OF THE NEAREST |
| | WATER'S EDGE OF EACH POOL SERVED BY THE FACILITIES. |
| | EXCEPTION: WHERE A SWIMMING POOL SERVES ONLY A |
| | DESIGNATED GROUP OF RESIDENTIAL DWELLING UNITS |
| | INCLUDING HOTEL ROOMS AND NOT THE GENERAL PUBLIC, |
| | POOLSIDE SANITARY FACILITIES ARE NOT REQUIRED IF ALL |
| | LIVING UNITS ARE WITHIN A 200-FOOT (60 960 MM) |
| | HORIZONTAL RADIUS OF THE NEAREST WATER'S EDGE, ARE NOT |
| | OVER THREE STORIES IN HEIGHT UNLESS SERVICED BY AN |
| | ELEVATOR, AND ARE EACH EQUIPPED WITH PRIVATE SANITARY |
| | FACILITIES. |
| | |
| | 8) A LIFE SAFTEY PLAN WAS SUBMITTED FOR LEVEL 1 (THE |
| | GROUND FLOOR). SUBMIT A LIFE SAFETY PLAN FOR THE ROOF |
| | TOP POOL LEVEL. FBC 107.2.1 |
| | |
| | 9) SHOW COMPLIANCE WITH FBC 454.1.6.2 RINSE SHOWER. A |
| | MINIMUM OF ONE RINSE SHOWER SHALL BE PROVIDED ON THE |
| | POOL DECK OF ALL OUTDOOR POOLS WITHIN THE PERIMETER OF |
| | THE FENCE. |
| | |
| | 10) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A |
| | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE |
| | CITY RE-SUBMITTAL FORM. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |