Plan Review Notes
Plan Review Notes For Permit 22040406
Permit Number 22040406
Review Stop P
Sequence Number 1
Notes
Date Text
2022-04-27 07:56:131ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22040406
 4/27/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE $1500 PERMIT VALUE IS A LOW VALUE FOR THE SCOPE
 OF WORK FOR THE POOL PROJECT. PROVIDE AN ITEMIZED COST
 BREAKDOWN THAT INCLUDES LABOR, MATERIALS, POOL
 EQUIPMENT, SITE WORK, AND DESIGN FEES- SEC. 109.3 WPB.
  
 2) SHEET 3: PROVIDE THE POOL TURNOVER RATE- SEC.
 R4501.6.6 FBC RES.
  
 3) SHEET 3: SUBMIT TOTAL DYNAMIC HEAD (TDH)
 CALCULATIONS FOR THE MAXIMUM SYSTEM FLOW. THE MAXIMUM
 FLOW OF THE PUMP FROM ITS PUMP CURVE AND THE SIMPLIFIED
 TOTAL DYNAMIC HEAD CALCULATION IS NO LONGER ALLOWED TO
 BE USED IN DETERMINING MAXIMUM SYSTEM FLOW RATE PER
 ANSI/APSP/ICC 7- 2013 SECS. 4.4.9, 4.4.9.1. THE 2013
 EDITION ADDRESSES FLOW RATE IN GALLONS PER MINUTE
 (GPM). IT REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES
 NOT EXCEED THE LISTED MAXIMUM FLOW RATE OF THE SUCTION
 OUTLET FITTING ASSEMBLY (DRAIN COVER). THE TDH
 CALCULATIONS MUST INCLUDE ALL OF THE SYSTEM COMPONENTS
 INCLUDING SUCTION AND RETURN PIPING, FITTINGS, VALVES,
 HEATER, FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS
 EXCEPT THE PUMP.
  
 4) SHEET 2: SUBMIT SPECS FOR THE REPLACED MAIN DRAIN
 ASSEMBLY- SEC. R4501.6.6 FBC RES.
  
 5) SHEET 3 SPECIFICATIONS: UPDATE CONFORMANCE STANDARDS
 IN NOTE 1 IN ACCORDANCE WITH SEC. R4501.6.1 FBC RES.
  
 6) SHEET 3: PLEASE PLACE A NOTE TO INDICATE A SEPARATE
 PERMIT IS REQUIRED FOR INSTALLATION OF THE GAS POOL
 HEATER- SECS. 105.1 & 107.1 WPB.
  
 7) SHEET 3: PLACE A NOTE TO INDICATE THERE IS AN
 EXISTING BACKFLOW PREVENTER FOR THE POTABLE WATER
 SERVICE OR A FL. LICENSED PLUMBING CONTRACTOR SHALL
 OBTAIN A SEPARATE PERMIT FOR INSTALLATION OF THE
 BACKFLOW PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB
 AND SEC. 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL
 BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT
 PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT.
 PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS
 DEPT.AT 561-822-2210 FOR FURTHER INFORMATION. A
 BACKFLOW PREVENTER SHALL ALSO BE INSTALLED AT THE
 AUTOFILL IF INSTALLED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  