2022-04-15 13:54:4004/15/22 FAILED - PER CITY CODE, IF A PATIO OR PAVED
 AREA IS PROVIDED ADJACENT TO OR SURROUNDING A POOL, IT
 SHALL BE DESIGNED TO DRAIN AWAY FROM THE POOL, BUT NOT
 ONTO ADJACENT PROPERTIES. THE SITE PLAN DOES NOT
 SPECIFY ANY DRAINAGE DIRECTIONS
  
 ADDITIONALLY, EVERY SWIMMING POOL SHALL BE ENCLOSED BY
 A FENCE OR SIMILAR STRUCTURE WHICH IS INSTALLED TO
 OBSTRUCT ACCESS BY PERSONS OTHER THAN THE OWNERS OR
 OCCUPANTS OF THE RESIDENCE WITHIN WHICH A SWIMMING POOL
 IS LOCATED. BARRIERS OR FENCES SHALL BE AT LEAST FOUR
 FEET IN HEIGHT ABOVE GRADE. THE SITE PLAN AND SURVEY DO
 NOT SHOW A FENCE. PLEASE KEEP IN MIND THAT ACCESS TO AN
 ACCESSORY SWIMMING POOL MUST BE THROUGH A BUILDING OR
 THROUGH A SELF-CLOSING AND SELF-LATCHING GATE OR
 THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES PLACED AT
 LEAST 54 INCHES ABOVE BOTTOM OF GATE
  