2022-05-03 07:44:341ST REVIEW FMC
 PERMIT: 22040124
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE DUCT SIZES ON THE MECHANICAL
 DRAWING. FBC 107.2.1
  
 2) PLEASE SHOW THE RETURN AIR PATH FROM ALL HABITUAL
 ROOMS WITH DOORS. FRC M1602.3
  
 3) PLEASE SHOW THE REQUIRED BATH EXHAUST FAN IN THE
 MASTER SHOWER AREA. FRC R303.3
  
 4) IS THERE A DUCTED HOOD TO BE INSTALLED ABOVE THE GAS
 RANGE? IF SO PLEASE PROVIDE THE CFM?S OF THE FAN. FRC
 M1503
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  