2022-07-20 07:22:00WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22040093
 ADD: 3501 GEORGIA AVE.
 CONT: SCP CONSTRUCTION GROUP
 TEL: 561-599-4107
 E-MAIL: SCPCONSTRUCTIONGROUP.COM
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. JULY 19TH/2022
 ACTION: DENIED
  
 1-5) COMPLIED.
  
 6A)
  
 6B
  
 6C)
  
 6D)2ND REQUEST. SHEET S-001, DETAIL 6 FRAME DETAIL
 SHOWS NEW WINDOW OPENING NEEDS TO SHOW COMPLIANCE WITH
 SECTIONS 2308.4.4, FRAMING AROUND WINDOWS, 2308.5.5 AND
 2308.5.5.1. HEADERS FULL LENGTH STUDS JACK STUDS AND
 ANCHORAGE WALL SYSTEM IS PART OF THE MAIN WIND FORCE
 RESISTING SYSTEM (MWFRS).
  
 7) COMPLIED.
  
 8) 2ND REQUEST. SEMI-COMPLIED. THE DESIGNER OF RECORD
 HAS STATED THE USE OF 2X6 @ 16 INCHES O. C.
 HOWEVER WHAT INFORMATION IS MISSING IS THE:
 SPECIES OF WOOD 2020 FBC-BUILDING CODE TABLE 2308.7(2)
 OR TABLE 2308.7.2(5)
 PROVIDE FROM WHICH TABLE THE INFORMATION IS TAKEN
 GRADE OF WOOD SAME TABLES
 ROOF LIVE LOAD SAME TABLES
 CENTER/ CENTER SAME TABLE
 ALLOWABLE SPAN SAME TABLE
 DEFLECTION LIMITS TABLE 1604.3
 1ST ROUND OF COMMENTS. SHEET 002 SHOWS A CLEAR SPAN OF
 13 FEET 11 INCHES WITH A 2X4 ROOF FRAMING SYSTEM @ 16
 INCHES ON CENTER. PLEASE PROVIDE FROM WHAT RAFTER SPAN
 TABLES YOU CAME UP WITH A 2X4 SPANNING 13 FEET 11
 INCHES PLEASE ALSO GIVE THE ROOF LIVE LOADS CEILING
 ATTACHED AND SPECIES AND GRADE OF WOOD. 2308.2.5 &
 TABLE 2308.7 RAFTER SPANS.
  
 9) SHEET 002 SHOWS COMPOSITE SHINGLES TO BE INSTALLED
 ON A ROOF WITH ? INCH SLOPE PER FOOT. PLEASE REVIEW
 SECTION 1507.2 FOR ASPHALT SHINGLES, MINIMUM SLOPE OF
 2:12 WITH DOUBLE UNDERLAYMENT. NEED TO SUPPLY A
 DIFFERENT ROOFING MATERIAL.
  
 10-11) COMPLIED
  
 12) 2ND REQUEST. SEMI-COMPLIED. PLEASE NOTE THE R-30
 CEILING INSULATION IF FIBERGLASS BATTS TAKES 8.25
 INCHES, WILL BE HARD TO GET THE DRYWALL FASTENED TO THE
 RAFTERS.
 EXTERIOR WALLS REQUIRE R-13 INSULATION NOT SHOWN ON
 PLANS. 2020 FBC-ENERGY CODE TABLE R 402.2.6.
 1ST ROUND OF COMMENTS. SHEET 002 DETAIL 5 THE EXTERIOR
 WALL DOES NOT SHOW COMPLIANCE WITH THE 2020
 FBC-C402.1.ENERGY CODE.
  
 13) IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected].
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  
 14) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  