Plan Review Notes
Plan Review Notes For Permit 22031568
Permit Number 22031568
Review Stop P
Sequence Number 1
Notes
Date Text
2022-04-15 14:14:201ST REVIEW FBC-2020 PLUMBING
 PERMIT REVISION 22031568
 4/15/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET ALS1.1. & ALS1.2: THE REVISED PLUMBING FIXTURE
 CALCULATIONS ARE APPROVED HOWEVER SEPARATE MALE AND
 FEMALE FACILITIES ARE REQUIRED FOR THE E CLASSROOM
 OCCUPANCIES PER SEC. 403.2 FBC P. PLEASE NOTE THAT
 FAMILY OR ASSISTED-USE TOILET FACILITIES ARE PERMITTED
 TO SERVE AS THE SEPARATE FACILITIES WHEN A BUILDING IS
 REQUIRED TO HAVE SEPARATE FACILITIES WITH ONLY ONE
 WATER CLOSET REQUIRED IN EACH- SEC. 403.2.1 FBC P.
 PLEASE CORRECT THE PLANS ACCORDINGLY.
  
 2) P101A: THE STRUCTURAL ENGINEER OF RECORD SHALL
 PROVIDE PIPE SLEEVING DETAILS FOR THE DRAIN PIPE
 PENETRATIONS THROUGH THE FOOTINGS- SEC. 305.3 FBC P &
 107.2.1 WPB. PLEASE PROVIDE THE TYPES AND SIZES OF PIPE
 SLEEVES ON THE PLAN.
  
 3) P201: NOTE 4 REFERENCES SHEET P204 FOR VENT BRANCH
 CONTINUATION, HOWEVER THE CONTINUATION IS NOT SHOWN THE
 SHEET- SEC. 107.2.1 WPB. IT APPEARS THE 2-INCH COMMON
 VENT AT NOTE 4 SERVING THE BRANCHES FOR THE BATHROOMS
 MAY BE EXCEEDING THE 45-FT. MAXIMUM DEVELOPED LENGTH OF
 THE VENT PER TABLE 906.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  