| Date |
Text |
| 2022-03-30 12:01:29 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | 1) SHEET D - 1 - THERE IS ARE INDICATIONS OF "REMOVE |
| | ALL FLOORING THROUGHOUT" IN THE MATER SUITE, DINING |
| | AREA AND LIVING AREA. |
| | |
| | HOWEVER, ON SHEET A - 1 THERE ARE INDICATIONS OF " |
| | EXIST. FLOOR TO REMAIN" IN THE DINING AREA & LIVING |
| | AREA AND NOTHING IN THE MASTER SUITE. |
| | |
| | FOR THE OFFICIAL RECORD, PLEASE PROVIDE |
| | CLARIFICATIONS/CONFIRMATION OF WHAT IS ACTUALLY BEING |
| | PROPOSED/COMPLETED AND CORRECT ON ALL SHEETS. |
| | |
| | 1A) SHEET A - 1 - THERE IS AN INDICATION WITHIN THE |
| | FLOOR FINISH SCHEDULE UNDER MODEL NAME/NUMBER OF |
| | "FLOORING TILE OVER PROFLEX....." |
| | |
| | TILE FLOORING COULD HAVE DIFFERENT MEANINGS AND IF NOT |
| | CERAMIC/PORCELAIN/MARBLE/CEMENT IT CAN BE |
| | VINYL/LAMINATE ETC AND IS MANUFACTURED FROM AROUND THE |
| | WORLD AND NOT ALL ARE TESTED AND MEETING LISTED AND |
| | NFPA STANDARDS. |
| | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE SPECIFIC |
| | TILE TYPE AND/OR PRODUCT SPEC SHEETS OF THE PROPOSED |
| | FINISHED FLOORING INDICATING THE FIRE BEHAVIOR RATING |
| | |
| | PER NFPA 101, CH 30 |
| | |
| | 30.3.3.3 INTERIOR FLOOR FINISH. |
| | 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN |
| | ACCORDANCE WITH |
| | SECTION 10.2. |
| | |
| | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH |
| | 10.2.2.2 |
| | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL |
| | HAVE A |
| | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. |
| | |
| | FLOORING/TILE IS MANUFACTURED AROUND THE WORLD AND NOT |
| | ALL ARE TESTED AND MEETING LISTED AND NFPA STANDARDS. |
| | |
| | IF THE PROPOSED FLOORING IS PORCELAIN/CERAMIC TILE, |
| | NATURAL STONE TILE, CONCRETE TILES, PRODUCT SPEC SHEETS |
| | WOULD NOT BE REQUIRED. |
| | |
| | PRODUCT SPEC SHEETS ARE REQUIRED FOR LVT, VINYL |
| | FLOORING, WOOD/VINYL LAMINATES, ETC. |
| | |
| | PLEASE PROVIDE THE TILE/FINISHED FLOORING PRODUCT |
| | TYPE/NAME AND SPEC SHEETS IF APPLICABLE |
| | . |
| | |
| | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET |
| | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE |
| | ABOVE. |
| | |
| | |
| | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE |
| | RE-SUBMITTAL OF THE ABOVE. |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |