Plan Review Notes
Plan Review Notes For Permit 22031125
Permit Number 22031125
Review Stop B
Sequence Number 1
Notes
Date Text
2022-05-25 10:19:47NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE THE PRODUCT APPROVAL FOR THE LOW
 SLOPE ROOFING - REVIEWED AND MARKED APPROVED BY THE
 DESIGNER OF RECORD FBC WPB 107.3.4
  
 2) PLEASE SHOW THE SLOPE FOR THE REAR LOW SLOPE ROOF
 DECK FBC R905
  
 3) PLEASE SHOW THE ATTIC ACCESS LOCATION AND OPENING
 SIZE - R807.1
  
 4) PLEASE SHOW THE FLOOR TRUSS DRAFT STOPPING LOCATION
 AND TYPE PER FBC R302.12
  
 5) PLEASE SHOW THE GARAGE CEILING DRYWALL THICKNESS AND
 TYPE TO COMPLY WITH FBC TABLE R302.6 FROM HABITABLE
 ROOMS ABOVE THE GARAGE. NOT LESS THAN 5/8-INCH TYPE X
 GYPSUM BOARD OR EQUIVALENT
  