| 2022-05-25 13:11:05 | SFR ADDITION |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE |
| | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS, AND |
| | ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE |
| | REVIEWED AND MARKED APPROVED BY THE BUILDING ADDITION |
| | DESIGNER OF RECORD FBC WPB 107.3.4 |
| | |
| | 2) PLEASE SHOW THE LOCATION OF THE REQUIRED SMOKE |
| | DETECTORS THROUGH OUT THE HOUSE PER FBC R314.2.2 |
| | ALTERATIONS, REPAIRS AND ADDITIONS. |
| | WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A |
| | PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE |
| | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL |
| | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS |
| | LOCATED AS REQUIRED FOR NEW DWELLINGS. R314.3 LOCATION. |
| | SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING |
| | LOCATIONS: |
| | 1.IN EACH SLEEPING ROOM. |
| | 2.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE |
| | VICINITY OF THE BEDROOMS. |
| | |
| | 3) DRAWING S-1 AND THE WIND DESIGN CALCULATIONS SHOW |
| | WIND DESIGN CRITERIA AS WIND SPEED 160 MPH, RISK |
| | CATEGORY I - SHOULD BE - 170 MPH, RISK CATEGORY II |
| | USING ASCE 7-16 PER FBC WPB SECTION 120 |
| | |
| | 4) DRAWING A-3 GENERAL NOTES SHOW CODE VERSION 2017 - |
| | SHOULD BE FBC 2020 |
| | |
| | 5) PLEASE SHOW THE TERMITE PROTECTION TO BE USED - FBC |
| | R318.1 |
| | |
| | 6) PLEASE PROVIDE A SURVEY. |
| | |
| | 7) SITE PLAN NEEDS TO SHOW THE LOT DRAINAGE (LOT CANNOT |
| | DRAIN TO THE NEIGHBORS PROPERTY) - FBC WPB 107.2.5 SITE |
| | PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED WITH THE |
| | APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A SITE |
| | PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF NEW |
| | CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, |
| | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES |
| | AND THE PROPOSED FINISHED GRADES, DEPICTING THE |
| | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD |
| | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT |
| | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| | INCLUDED ON A BOUNDARY LINE SURVEY. (PLEASE PROVIDE CUT |
| | SECTIONS FOR ANY PROPOSED WATER RETAINING SWALES) |
| | |
| | |
| | |