| 2022-03-15 15:13:18 | 03/15/22 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS |
| | |
| | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| | |
| | 1. A SUB GAS PERMIT IS REQUIRED BY A LICENSED |
| | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS |
| | TO THE FBC SEC. 105.1. |
| | |
| | 2. ON SHEET A-8; |
| | |
| | A. THE SANITARY ISOMETRIC DIAGRAM IS HARD TO READ AS IT |
| | DOES NOT MATCH THE FLOOR PLAN. WOULD YOU PLEASE CORRECT |
| | TO MATCH PLANS PER THE WPB AMENDMENTS TO THE FBC SEC. |
| | 107.3.5.3 (12) RESIDENTIAL PLUMBING? |
| | |
| | B. IT DOES NOT SHOW THE WASHING MACHINE ON THE FLAT |
| | PLANS, BUT YOU HAVE IT SHOWN ON ISOMETRIC, AND THERE IS |
| | A SHOWER THAT IS NOT VENTED CORRECTLY. WOULD YOU PLEASE |
| | SHOW AND LABEL PER THE WPB AMENDMENTS TO THE FBC SEC. |
| | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENT? |
| | |
| | C. THE ORIENTATION OF THE LAVS AND OTHER FIXTURES IS |
| | CHALLENGING TO MATCH. WOULD YOU PLEASE CORRECT PER THE |
| | WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. |
| | |
| | D. THE WASHING MACHINE AND LAUNDRY ARE NOT VENTED |
| | CORRECTLY. WOULD YOU PLEASE CORRECT PER THE WPB |
| | AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. |
| | |
| | E. THE RESTROOM WITH THE THREE LAVS LOOKS LIKE THE |
| | WATER CLOSET HAS A DRY VENT ON A WET VENT PER THE FBC |
| | 2020 R P3108.2.1 HORIZONTAL WET VENT. |
| | |
| | F. WOULD YOU PLEASE LABEL ALL BATHROOMS PER THE WPB |
| | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. |
| | |
| | G. WOULD YOU PLEASE PROVIDE A SCOPE OF WORK ON WHAT THE |
| | PLUMBING WORK CONSISTS OF PER THE WPB AMENDMENTS TO THE |
| | FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | H. PIPES SIZES ARE MISSING ON THE ISOMETRIC. WOULD YOU |
| | PLEASE PROVIDE PER THE WPB AMENDMENTS TO THE FBC |
| | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | I. ON SHEET A-3, IT DOES NOT MATCH THE FLOOR PLAN A-8 |
| | IN THE LAUNDRY ROOM. WOULD YOU PLEASE CORRECT PER THE |
| | WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. |
| | |
| | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA |
| | |
| | WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON |
| | REQUEST. |
| | LUIS A. CRESPO |
| | PLUMBING PLAN EXAMINER / INSPECTOR |
| | EMAIL: [email protected] OFFICE: 561 805-6720 |
| | |