| Plan Review Notes For Permit 22030526 |
| Permit Number |
22030526 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2022-04-28 12:40:05 | 22030526 295 LAKEVIEW AVE | | | | | | PLUMBING COMMENTS: APPROVED | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | REQUIRED DRINKING FOUNTAIN IS EXISTING AND LOCATION | | | COMPLIES WITH FPC 403.5. SEE PLAN SHEET A2.01 | | | | | | | | | PROVISO: SEE PLAN SHEET A2.07 | | | TOILET PAPER DISPENSERS SHALL BE 7 INCHES MINIMUM AND 9 | | | INCHES MAXIMUM IN FRONT OF THE WATER CLOSET TO THE | | | CENTERLINE OF THE DISPENSER. FAC 604.8 | | | | | | CLARIFICATION: SEE PLAN SHEET A2.07 | | | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, | | | 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE | | | FINISH FLOOR TO THE TOP OF THE GRIPPING SURFACE. FAC | | | 609.4 | | | |
|