| Date |
Text |
| 2022-04-18 09:13:59 | BUILD OUT |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE SHOW THE WALL FINISH FOR THE WALLS |
| | SURROUNDING THE MOP SINK - FBC 1210.2.2 WALLS AND |
| | PARTITIONS. |
| | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT |
| | CONSIDERED A HARD SURFACE) |
| | |
| | 2) PLEASE SHOW THE DIMENSIONS FOR THE KITCHEN - FBC |
| | 1208.1 KITCHENS SHALL HAVE A CLEAR PASSAGEWAY OF NOT |
| | LESS THAN 3 FEET (914 MM) BETWEEN COUNTER FRONTS AND |
| | APPLIANCES OR COUNTER FRONTS AND WALLS. |
| | |
| | 3) PLEASE SHOW THE ACCESSIBLE BAR SEATING COUNTER TOP |
| | HEIGHT - FBC A 902.3 HEIGHT. |
| | THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE |
| | 28 INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 4) DRAWING 1.4A - SECTION 2-1.4A DOES NOT SHOW THE |
| | ACCESSIBLE BAR SEATING - PER THE FLOOR PLAN 1.0A |
| | |
| | 5) DRAWING 1.6A DETAIL 10 - THE CASHIER COUNTER HEIGHT |
| | NEEDS TO COMPLY WITH FBC 904.4 SALES AND SERVICE |
| | COUNTERS. |
| | SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH |
| | 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE |
| | COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR |
| | SERVICE COUNTER TOP. |
| | |
| | 6) ACCESSIBLE RESTROOM - PLEASE SHOW THE DIMENSIONS FOR |
| | THE GRAB BARS, MIRROR. ETC FBC ACCESSIBILITY CHAPTER 6 |
| | |
| | 7) ACCESSIBLE RESTROOM - DOOR CANNOT SWING INTO THE |
| | FIXTURE CLEAR FLOOR SPACE (PLEASE SHOW THE CLEAR FLOOR |
| | SPACE IF USING THE EXCEPTION) - FBC A 603.2.3 DOOR |
| | SWING. |
| | DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR |
| | CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE |
| | PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. |
| | EXCEPTIONS: (2) WHERE THE TOILET ROOM OR BATHING ROOM |
| | IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING |
| | WITH 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC |
| | OF THE DOOR SWING, DOORS SHALL BE PERMITTED TO SWING |
| | INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR |
| | ANY FIXTURE. |
| | |
| | 8) ACCESSIBLE RESTROOM - PLEASE SHOW THE DOOR |
| | MANEUVERING CLEARANCE (18" BESIDE THE LATCH SIDE) TO |
| | EXIT THE RESTROOM - FBC A 404.2.4 |
| | |