Plan Review Notes
Plan Review Notes For Permit 22030512
Permit Number 22030512
Review Stop B
Sequence Number 1
Notes
Date Text
2022-04-18 09:13:59BUILD OUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE WALL FINISH FOR THE WALLS
 SURROUNDING THE MOP SINK - FBC 1210.2.2 WALLS AND
 PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT
 CONSIDERED A HARD SURFACE)
  
 2) PLEASE SHOW THE DIMENSIONS FOR THE KITCHEN - FBC
 1208.1 KITCHENS SHALL HAVE A CLEAR PASSAGEWAY OF NOT
 LESS THAN 3 FEET (914 MM) BETWEEN COUNTER FRONTS AND
 APPLIANCES OR COUNTER FRONTS AND WALLS.
  
 3) PLEASE SHOW THE ACCESSIBLE BAR SEATING COUNTER TOP
 HEIGHT - FBC A 902.3 HEIGHT.
 THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE
 28 INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 4) DRAWING 1.4A - SECTION 2-1.4A DOES NOT SHOW THE
 ACCESSIBLE BAR SEATING - PER THE FLOOR PLAN 1.0A
  
 5) DRAWING 1.6A DETAIL 10 - THE CASHIER COUNTER HEIGHT
 NEEDS TO COMPLY WITH FBC 904.4 SALES AND SERVICE
 COUNTERS.
 SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH
 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE
 COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR
 SERVICE COUNTER TOP.
  
 6) ACCESSIBLE RESTROOM - PLEASE SHOW THE DIMENSIONS FOR
 THE GRAB BARS, MIRROR. ETC FBC ACCESSIBILITY CHAPTER 6
  
 7) ACCESSIBLE RESTROOM - DOOR CANNOT SWING INTO THE
 FIXTURE CLEAR FLOOR SPACE (PLEASE SHOW THE CLEAR FLOOR
 SPACE IF USING THE EXCEPTION) - FBC A 603.2.3 DOOR
 SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
 EXCEPTIONS: (2) WHERE THE TOILET ROOM OR BATHING ROOM
 IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING
 WITH 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC
 OF THE DOOR SWING, DOORS SHALL BE PERMITTED TO SWING
 INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR
 ANY FIXTURE.
  
 8) ACCESSIBLE RESTROOM - PLEASE SHOW THE DOOR
 MANEUVERING CLEARANCE (18" BESIDE THE LATCH SIDE) TO
 EXIT THE RESTROOM - FBC A 404.2.4
  