Plan Review Notes
Plan Review Notes For Permit 22030336
Permit Number 22030336
Review Stop G
Sequence Number 1
Notes
Date Text
2022-03-10 08:42:0903/10/22 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. NOTE: THE CITY OF WEST PALM BEACH HAS NO RECORD OF
 EXISTING GAS PERMITS WITH INSPECTIONS OF THE CURRENT
 SYSTEM. A COMPLETE EVALUATION OF ALL GAS SYSTEMS AND
 EQUIPMENT WILL BE DONE ON THIS REVIEW, AND IF NOT TO
 CODE, IT MAY NEED TO BE BOUT UP TO CODE COMPLIANCE AT
 THE OWNER?S EXPENSE PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  
 2. WOULD YOU PLEASE PROVIDE A SCOPE OF WORK THAT IS
 BEING DONE? IT IS UNCLEAR IF THE WORK WILL BE DONE PER
 THE WPB AMENDMENTS TO THE FBC SEC. 101.2 SCOPE.
  
 3. THE PHYSICAL ADDRESS OF THE RESIDENCE MUST BE ON
 PLANS IN FULL, NUMBER, STREET, CITY, STATE, AND ZIP
 CODE PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. WOULD YOU PLEASE SUBMIT THE ISOMETRIC DRAWING THAT
 CLEARLY SHOWS THE LENGTH OF ALL CUT SECTIONS OF PIPE
 PER 2020 FBC RES. SECS. G2413.4.1, G2413.4.2.
  
 5. THIS TANKLESS UNIT CALL FOR A 10.5? WATER COLUMN,
 AND THE SERVICE METER DISCHARGES IS A 12? WATER COLUMN
 REQUIRING A REGULATOR FOR THIS UNIT AS PER THE
 MANUFACTURER'S SPECIFICATION. SUBMIT MANUFACTURER?S
 SPECIFICATIONS FOR THE PRESSURE REGULATORS IF
 APPLICABLE. REGULATORS INSTALLED ON THE EXTERIOR OF THE
 BUILDING SHALL BE APPROVED FOR OUTDOOR INSTALLATION PER
 THE 2020 FBC RES. SEC. G2421.1 OR 410.1.
  
 6. IS THE DRYER IN A CLOSET OR OPEN SPACE? WOULD YOU
 PLEASE SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC RES. SEC. G2407.1 AND G2439.4 (CLOTHES DRYERS). IF
 THE LOUVER IS USED, SHOW THE LOUVERS' LOCATIONS THAT
 ARE BEING INSTALLED FOR THE COMBUSTION AIR. THE LOUVERS
 CANNOT BE LOCATED ON AN EXTERIOR WALL THAT IS FIRE
 RATED AS THE FIRE RATING OF THE WALL MUST BE MAINTAINED
 PER THE WPB AMENDMENTS TO FBC SEC.107.2.1.
  
 7. SHOW THE DISTANCE FROM THE POINT OF DELIVERY (GAS
 METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER THE 2020 FBC
 FG SEC. 402.4.1 OR 2020 FBC RES. SEC. G2413.4.1.
  
 8. LIST THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL
 BTU LOAD ON THE SYSTEM. REFER TO THE 2020 FBC FG SECS.
 401.8 THROUGH 402.6.1 AND TABLES 402.4 (1) THROUGH
 402.4 (37) OR 2020 FBC RES. SEC. G2413.
  
 9. WOULD YOU PLEASE PROVIDE WHAT TYPE OF GAS (LP OR
 NATURAL) IS BEING USED PER THE WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 10. INDICATE THE SYSTEM'S DELIVERY PRESSURE (PSI) ON
 THE PLAN PER THE 2020 FBC FG SEC. 402.2 OR 2020 FBC
 RES. SEC. G2413.2.
  
 11. WOULD YOU PLEASE PROVIDE MANUFACTURES
 SPECIFICATIONS FOR GAS TANKLESS, DYER, AND GENERATOR
 EQUIPMENT TO VERIFY COMPLIANCE WITH 2020 FBC RES. SEC.
 G2408.1. GAS APPLIANCES SHALL BE LISTED AND LABELED.
 THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES/EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION PER THE 2020 FBC RES. SEC. G2413.2 AND
 G2404.3.
  
 12. IF UTILITIES PROVIDE A REGULATOR, NO SPECIFICATIONS
 ARE REQUIRED BUT SUBMIT THE MANUFACTURER?S
 SPECIFICATIONS FOR THE PRESSURE REGULATORS INSTALLED AT
 TANKLESS OR ANY OTHER LOCATION. REGULATORS INSTALLED ON
 THE EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR
 OUTDOOR INSTALLATION PER THE 2020 FBC RES. SEC.
 G2421.1. A REGULATOR IS REQUIRED TO BRING THE SYSTEM
 DOWN TO 10.5 WC ON THE HEART, BUT THE FPU REGULATOR MAY
 STEP DOWN FOR THIS SYSTEM.
  
 13. WOULD YOU PLEASE SUBMIT A HOUSE PLAN SHOWING THE
 LOCATION OF THE TANK-LESS WATER HEATER AND THE LOCATION
 AND DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN
 RELATION TO THE WATER HEATER? THE LOCATION OF THE WATER
 HEATER SHALL COMPLY WITH THE MANUFACTURER'S
 INSTALLATION INSTRUCTIONS. THE HOUSE PLAN CAN BE
 HAND-DRAWN PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.2.1. INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 14. HOT WATER LINES NOT IN CONDITION SPACE NEED TO BE
 INSULATED WITH A MINIMUM R-3 PER THE 2020 FBC SEC. RE
 403.5.3. WOULD YOU PLEASE NOTE ON PLANS. IF APPLICABLE.
  
 15. CONDENSATE FOR TANKLESS NEEDS TO BE 1' AWAY FROM
 THE STRUCTURE PER THE 2020 FBC SEC. R318.5. IF
 APPLICABLE. WOULD YOU PLEASE NOTE ON PLANS. IF
 APPLICABLE.
  
 16. THE CLAIMED VALUE APPEARS TO BE UNDERESTIMATED ON
 THE APPLICATION; PLEASE PROVIDE AN ITEMIZED DOCUMENT
 PER THE WPB AMENDMENTS TO THE FBC 109.3. BUILDING
 PERMITS VALUATIONS. THE PLUMBING APPLICATION AND THE
 OVERALL VALUE IS LOW. WPB AMENDMENTS TO THE FBC 109.3
 BUILDING PERMITS VALUATIONS. SUPPOSE, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF THE
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION. IN THAT CASE, THE
 PERMIT SHALL BE DENIED UNLESS THE APPLICANT CAN SHOW
 DETAILED QUANTITY ESTIMATES AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE APPROVAL
 OF THE BUILDING OFFICIAL. THE VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE FOR
 PERMITTING PURPOSES, INCLUDING STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE
 WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD, AND PROFIT, EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. THE FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. THE
 VALUE HAS BEEN CHANGED, AND FEES AND NOC ARE REQUIRED.
  
 17. WOULD YOU PLEASE SUBMIT THE SIZING TABLE USED IN
 THE DESIGN FOR THE GAS SYSTEM OR PLACE A NOTE ON BOTH
 SETS OF PLANS LISTING THE SIZING TABLES FROM GAS CODES
 OR ANOTHER STANDARD THAT WAS USED IN THE DESIGN OF THIS
 SYSTEM PER THE 2020 FBC RES. SEC. G2413.3.
  
 18. WOULD YOU PLEASE LABEL THE SHUTOFF VALVES AND DRIP
 LEGS ON GAS ISOMERIC PER THE 2020 FBC FG SEC. 409.5 OR
 2020 FBC RES. SEC. G2420.5.
  
 19. A LICENSED CONTRACTOR REQUIRES A GENERATOR PERMIT
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENT TO THE FBC
 SEC. 105.1.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON
 REQUEST.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved