| 2022-08-02 10:59:10 | CREATING 2 UNITS |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE SHOW STAIR HAND RAIL EXTENSION AT THE BOTTOM |
| | OF THE STAIRS TO SLOPE PER FBC 1014.6 HANDRAIL |
| | EXTENSIONS. |
| | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING |
| | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN |
| | ADJACENT FLIGHT OF STAIRS OR RAMP RUN. WHERE HANDRAILS |
| | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL |
| | EXTEND HORIZONTALLY NOT LESS THAN 12 INCHES (305 MM) |
| | BEYOND THE TOP RISER AND CONTINUE TO SLOPE FOR THE |
| | DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. |
| | |
| | 2) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS |
| | "REFLECTIVE SURFACE" WHEN SHOWING THE DIMENSION FROM |
| | THE FLOOR TO THE BOTTOM OF THE MIRROR - FBC A 603.3 |
| | MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 3) ACCESSIBLE RESTROOM = PLEASE SHOW THE TOILET PAPER |
| | DISPENSER DIMENSIONS FROM THE FRONT OF THE TOILET AND |
| | HEIGHT FROM THE FLOOR - FBC A 604.7 DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| | SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL |
| | NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES |
| | NOT ALLOW CONTINUOUS PAPER FLOW. |
| | |
| | 4) PLEASE SHOW THE RAMP EDGE PROTECTION (SHOW THE GUARD |
| | RAIL BOTTOM RAIL WITHIN 4" OF THE RAMP) FBC A 405.9 |
| | EDGE PROTECTION. |
| | EDGE PROTECTION COMPLYING WITH 405.9.1 OR 405.9.2 SHALL |
| | BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE |
| | OF RAMP LANDINGS. 405.9.2CURB OR BARRIER. |
| | A CURB OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE |
| | PASSAGE OF A 4 INCH (100 MM) DIAMETER SPHERE, WHERE ANY |
| | PORTION OF THE SPHERE IS WITHIN 4 INCHES (100 MM) OF |
| | THE FINISH FLOOR OR GROUND SURFACE. |
| | |
| | 5) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE |
| | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVALS FOR THE EXTERIOR STOREFRONT WINDOWS |
| | AND DOORS - ALL PRODUCT APPROVALS NEED TO BE REVIEWED |
| | AND MARKED APPROVED BY THE DESIGNER OF RECORD FBC WPB |
| | 107.3.4 |
| | |
| | 6) CANNOT REUSE STOREFRONT WINDOWS UNLESS YOU HAVE A |
| | CURRENT PRODUCT APPROVAL FOR THEM - FBC EXISTING 707.4 |
| | REPLACEMENT OF WINDOWS AND DOORS. |
| | THE REPLACEMENT OF GARAGE DOORS, EXTERIOR DOORS, |
| | SKYLIGHTS, AND OPERATIVE AND INOPERATIVE WINDOWS SHALL |
| | BE DESIGNED AND CONSTRUCTED TO COMPLY WITH CHAPTER 16 |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 7) ELEVATION CERTIFICATE PROVIDED IS INCORRECT - PALM |
| | BEACH COUNTY FLOOD MAP SHOWS BUILDING IN A FLOOD ZONE |
| | (AE 12.10) - NFIP - JOB IS A SUBSTANTIAL IMPROVEMENT |
| | JOB VALUE + 5 YEAR ACCUMULATION = 1,015,272.00 - |
| | BUILDING VALUE = 1,355,080.00 - THE BUILDING LOWEST |
| | FLOOR ELEVATION NEEDS TO BE AT 14.10 NAVD - PLEASE |
| | PROVIDE AN ELEVATION CERTIFICATE TO VERIFY THE LOWEST |
| | FLOOR ELEVATION - ORDINANCE NO. 4729-17 SEC. 18-35 (A) |
| | AND (B) |