| Plan Review Notes For Permit 22030266 |
| Permit Number |
22030266 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-04-04 12:35:50 | COMMERCIAL REMODEL AND ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) BUILDING DEMOLITION NEEDS TO BE ON A SEPARATE | | | PERMIT. | | | | | | 2) PLEASE SHOW THE RESTROOM WALL FINISH TO COMPLY WITH | | | FBC 1210.2.2 WALLS AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR - (DRYWALL IS NOT | | | CONSIDERED A HARD SURFACE) | | | | | | 3) PLEASE SHOW RESTROOM BASE BOARD (SHOULD NOT BE WOOD) | | | TO COMPLY WITH FBC 1210.2.1 FLOORS AND WALL BASES. | | | IN OTHER THAN DWELLING UNITS, TOILET, BATHING AND | | | SHOWER ROOM FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE. THE INTERSECTIONS OF SUCH | | | FLOORS WITH WALLS SHALL HAVE A SMOOTH, HARD, | | | NONABSORBENT VERTICAL BASE THAT EXTENDS UPWARD ONTO THE | | | WALLS NOT LESS THAN 4 INCHES (102 MM). | | | |
|