2022-04-30 08:41:30PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1.PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT
 APPROVAL OR MIAMI-DADE NOA, APPROVED UNDER THE 2020
 FBC, FOR THE PROPOSED WINDOWS AND DOORS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 NOTICE: VERIFY EGRESS AT NEW SLEEPING ROOM.
  
 R310.2.1MINIMUM OPENING AREA.
  
 EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE A NET
 CLEAR OPENING OF NOT LESS THAN 5.7 SQUARE FEET (0.530
 M2). THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS
 SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF
 THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE
 INSIDE. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS
 THAN 24 INCHES (610 MM) AND THE NET CLEAR WIDTH SHALL
 BE NOT LESS THAN 20 INCHES (508 MM).
  
 EXCEPTION: GRADE FLOOR OR BELOW GRADE OPENINGS SHALL
 HAVE A NET CLEAR OPENING OF NOT LESS THAN 5 SQUARE FEET
 (0.465 M2).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.