Plan Review Notes
Plan Review Notes For Permit 22021436
Permit Number 22021436
Review Stop B
Sequence Number 1
Notes
Date Text
2022-03-24 09:41:47BUILD OUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVAL FOR THE NEW EXTERIOR DOOR - ALL
 PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE ARCHITECT OF RECORD FBC WPB 107.3.4
  
 2) DRAWING G200 DETAILS A AND B SHOWS WALL TILE AT A
 HEIGHT OF 3' 1 5/8" - PLEASE SHOW WALL FINISH AT
 TOILETS AND URINALS TO COMPLY WITH FBC 1210.2.2 WALLS
 AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR (DRYWALL IS NOT
 CONSIDERED A HARD SURFACE).
  
 3) PLEASE SHOW IF TERMITE TREATMENT IS REQUIRED -
 1816.1.2
 IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE
 PREVENTION, SOIL AREA DISTURBED AFTER INITIAL CHEMICAL
 SOIL TREATMENT SHALL BE RETREATED WITH A CHEMICAL SOIL
 TREATMENT
  
 4) ACCESSIBLE RESTROOMS - PLEASE SHOW THE LOCATION
 DIMENSIONS FOR THE TOILET PAPER HOLDER - FBC A 604.7
 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48
 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND
 SHALL NOT BE LOCATED BEHIND GRAB BARS.
  
 5) ACCESSIBLE RESTROOMS - PLEASE USE THE WORDS
 "REFLECTIVE SURFACE" OF THE MIRROR WHEN REFERRING TO
 THE DIMENSIONS FROM THE FLOOR - FBC A 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 6) ACCESSIBLE RESTROOM - PLEASE SHOW RESTROOM SIGNAGE
 HEIGHT TO COMPLY WITH FBC A 703.4.1 HEIGHT ABOVE FINISH
 FLOOR OR GROUND.
 TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES
 (1220 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND
 SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST
 TACTILE CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE
 THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE
 BASELINE OF THE HIGHEST TACTILE CHARACTER.
  
 7) ACCESSIBLE RESTROOM - VERTICAL GRAB BAR IS NOT
 REQUIRED PER FBC ACCESSIBILITY - PLEASE SHOW THE
 CLEARANCE ABOVE THE GRAB BARS TO COMPLY WITH FBC A
 609.3 THE SPACE BETWEEN THE GRAB BAR AND PROJECTING
 OBJECTS ABOVE SHALL BE 12 INCHES (305 MM) MINIMUM.