| Date |
Text |
| 2022-03-24 09:41:47 | BUILD OUT |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE |
| | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVAL FOR THE NEW EXTERIOR DOOR - ALL |
| | PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED |
| | APPROVED BY THE ARCHITECT OF RECORD FBC WPB 107.3.4 |
| | |
| | 2) DRAWING G200 DETAILS A AND B SHOWS WALL TILE AT A |
| | HEIGHT OF 3' 1 5/8" - PLEASE SHOW WALL FINISH AT |
| | TOILETS AND URINALS TO COMPLY WITH FBC 1210.2.2 WALLS |
| | AND PARTITIONS. |
| | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| | THAN 4 FEET (1219 MM) ABOVE THE FLOOR (DRYWALL IS NOT |
| | CONSIDERED A HARD SURFACE). |
| | |
| | 3) PLEASE SHOW IF TERMITE TREATMENT IS REQUIRED - |
| | 1816.1.2 |
| | IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE |
| | PREVENTION, SOIL AREA DISTURBED AFTER INITIAL CHEMICAL |
| | SOIL TREATMENT SHALL BE RETREATED WITH A CHEMICAL SOIL |
| | TREATMENT |
| | |
| | 4) ACCESSIBLE RESTROOMS - PLEASE SHOW THE LOCATION |
| | DIMENSIONS FOR THE TOILET PAPER HOLDER - FBC A 604.7 |
| | DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| | SHALL NOT BE LOCATED BEHIND GRAB BARS. |
| | |
| | 5) ACCESSIBLE RESTROOMS - PLEASE USE THE WORDS |
| | "REFLECTIVE SURFACE" OF THE MIRROR WHEN REFERRING TO |
| | THE DIMENSIONS FROM THE FLOOR - FBC A 603.3 MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 6) ACCESSIBLE RESTROOM - PLEASE SHOW RESTROOM SIGNAGE |
| | HEIGHT TO COMPLY WITH FBC A 703.4.1 HEIGHT ABOVE FINISH |
| | FLOOR OR GROUND. |
| | TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES |
| | (1220 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND |
| | SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST |
| | TACTILE CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE |
| | THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE |
| | BASELINE OF THE HIGHEST TACTILE CHARACTER. |
| | |
| | 7) ACCESSIBLE RESTROOM - VERTICAL GRAB BAR IS NOT |
| | REQUIRED PER FBC ACCESSIBILITY - PLEASE SHOW THE |
| | CLEARANCE ABOVE THE GRAB BARS TO COMPLY WITH FBC A |
| | 609.3 THE SPACE BETWEEN THE GRAB BAR AND PROJECTING |
| | OBJECTS ABOVE SHALL BE 12 INCHES (305 MM) MINIMUM. |