| 2022-03-22 07:34:17 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2020 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 22021141 |
| | ADD: 4 HARVARD CIRCLE # 700 |
| | CONT: CHANDLER CONSTRUCTION |
| | TEL: 561-6394 |
| | E-MAIL: [email protected] |
| | |
| | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. MARCH 22ND/ 2022 |
| | ACTION: DENIED |
| | |
| | 1) THE COVER SHEET UNDER THE HEADING OF CODE SUMMARY |
| | 2.4 PLUMBING REQUIREMENTS STATES AN OCCUPANT LOAD 63 |
| | PERSONS THEN PROVIDES 2,344/15 = 16 OCCUPANTS. BELOW |
| | STATES PROVIDED AND REQUIRED FIXTURES 1 EACH. THE LIFE |
| | SAFETY PLAN SHOWS ONLY ONE RESTROOM. PLEASE REVIEW IN |
| | THE 2020 SECTION 2902.2 SEPARATE FACILITIES REQUIRED, |
| | EXCEPTION 2 IS TOTAL OCCUPANT LOAD INCLUDING BOTH |
| | EMPLOYEES AND CUSTOMERS, OF 15 OR FEWER. |
| | |
| | 2) SHEET A3.2 INTERIOR ELEVATIONS, DETAIL 6 COPY |
| | ELEVATION INDICATES THE COUNTERTOP AT 36 INCHES ABOVE |
| | FINISH FLOOR. 2020 FBC-ACCESSIBILITY CODE SECTION 902.3 |
| | HEIGHT. THE TOPS OF WORK SURFACES SHALL BE 28 INCHES |
| | MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR |
| | GROUND. |
| | |
| | 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| | REVIEW CYCLE. |
| | |
| | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| | PART-TIME/ SEMI-RETIRED. |
| | |
| | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| | BACK INTO THE OFFICE CALL |
| | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| | THANK YOU. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |