| Plan Review Notes For Permit 22021073 |
| Permit Number |
22021073 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2022-07-12 09:46:03 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PROPOSED WORK INCLUDES BORING HOLES THROUGH | | | EXISTING FLOOR SLABS IN A THRESHOLD BUILDING (MORE THAN | | | 3 STORIES IN HEIGHT) WHICH IS STRUCTURAL WORK. THIS | | | PROJECT REQUIRES A STATE OF FLORIDA LICENSED GENERAL | | | CONTRACTOR (CGC) TO PULL A BUILDING PERMIT FOR THE | | | STRUCTURAL WORK. THE PENETRATION FIRESTOP SYSTEM FOR | | | THE FIRE-RESISTANCE RATED FLOOR ASSEMBLIES SHOULD ALSO | | | BE INCLUDED IN THE WORK OF THE GC. FS 489 & FS 553.71 | | | | | | 2) A THRESHOLD BUILDING SPECIAL INSPECTOR WILL BE | | | REQUIRED TO PERFORM THE STRUCTURAL INSPECTIONS FOR THIS | | | PROJECT. SUBMIT THE REQUIRED THRESHOLD INSPECTION | | | DOCUMENTS. FBC AMENDMENTS 110.8.1 | | | | | | 3) PROVIDE A FIRESTOP DETAIL WITH A LISTED SYSTEM FOR | | | THE FLOOR ASSEMBLY PENETRATIONS. FBC 714.2 | | | CREATED STOP FOR BUILDING TO REVIEW RATED ASSEMBLIES | | | FOR NEW PENTETRATIONS MADE BY FLOOR DRAINS. |
|