| Plan Review Notes For Permit 22021046 |
| Permit Number |
22021046 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2022-06-01 12:52:23 | APARTMENT RENOVATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PRODUCT APPROVAL FL14108 FOR THE FIXED GLASS WINDOWS | | | DOES NOT MEET IMPACT REQUIREMENTS - PLEASE PROVIDE THE | | | REQUIRED SHUTTER PRODUCT APPROVALS - FBC 1609.1.2 | | | | | | 2) DRAWING A6 STAIR NOTE #5 SHOWS MAXIMUM RISER HEIGHT | | | AT 7.5" - I ADDED A NOTE TO DRAWING A6 - STATING THAT | | | THE STAIR RISER HEIGHT MAXIMUM TO BE 7" PER FBC | | | 1011.5.2 | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|