| Date |
Text |
| 2022-03-29 14:16:19 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1 |
| | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| | MANUAL REVISED 2017 |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 |
| | 7TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 22021014 2427 PRESIDENTIAL WAY # 404 |
| | |
| | 2ND REVIEW |
| | |
| | PLUMBING COMMENTS: DENIED |
| | |
| | 1.NEW COMMENT: PLAN SHEET P301/NOTE 212; IT IS BROUGHT |
| | TO OUR ATTENTION BY THE GENERAL MANAGER OF THE CONDO |
| | ASSOCIATION THAT THE RELOCATED DRAIN PIPE FOR THE |
| | KITCHEN SINK IS A WASTE STACK VENT WHICH RISES |
| | VERTICALLY THROUGH THE KITCHEN WALL IN THE GENERAL |
| | VICINITY OF THE KITCHEN SINK. PLEASE NOTE THAT WASTE |
| | STACK VENTS SHALL NOT BE OFFSET VERTICALLY OR |
| | HORIZONTALLY PER FBC PL 913.2 AND AS SUCH SHALL REMAIN |
| | IN THE ORIGINAL LOCATION. PER WPB FBC 107.2.1, MAKE |
| | CORRECTION TO DRAWING AS NEEDED AND RESUBMIT. |
| | |
| | 2.REVISED P-801; SANITARY RISER DIAGRAMS ARE |
| | INCOMPLETE. FLOOR PENETRATIONS ARE SHOWN; HOWEVER, |
| | THERE IS NO DRAINAGE OR VENTING SHOWN. PER WPB FBC |
| | 107.2.1, CORRECT AND RESUBMIT. |
| | |
| | 3.REGARDING THE NEWLY PROVIDED SHOWER |
| | THRESHOLD/LINER/WALL DETAIL, PER WPB FBC 107.2.1, |
| | PLEASE PROVIDE THE FOLLOWING INFORMATION AS WAS |
| | PREVIOUSLY REQUESTED. |
| | ***A) DETAIL SHALL INCLUDE ALL COMPONENTS OF FBC PL |
| | 421.5.2 AS FOLLOWS: |
| | LINERS SHALL TURN UP ON ALL SIDES NOT LESS THAN 2 |
| | INCHES ABOVE THE FINISHED THRESHOLD LEVEL |
| | LINERS SHALL BE RECESSED AND FASTENED TO AN APPROVED |
| | BACKING |
| | LINERS SHALL NOT BE NAILED OR PERFORATED AT ANY POINT |
| | LESS THAN 1 INCH ABOVE THE FINISHED THRESHOLD |
| | LINERS SHALL BE PITCHED ONE-FOURTH UNIT VERTICAL IN 12 |
| | UNITS HORIZONTAL (2-PERCENT SLOPE) AND SHALL BE SLOPED |
| | TOWARD THE FIXTURE DRAIN |
| | LINERS SHALL BE SECURELY FASTENED TO THE WASTE OUTLET |
| | AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT JOINT |
| | BETWEEN THE LINER AND THE OUTLET |
| | FLOORS OR RECEPTORS UNDER SHOWER COMPARTMENTS SHALL BE |
| | LAID ON, AND SUPPORTED BY, A SMOOTH AND STRUCTURALLY |
| | SOUND BASE. |
| | ***B) LINER MATERIAL (SPECIFY LINER MATERIAL COMPLYING |
| | WITH ONE OF THE FOLLOWING FBC PL SECTIONS-421.5.2.1, |
| | 421.5.2.2, 421.5.2.3, 421.5.2.4, 421.5.2.5 OR |
| | 421.5.2.6.) |
| | ***C) FBC PL 421.4.1: WALLS IN SHOWER COMPARTMENTS |
| | SHALL BE CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND |
| | NONABSORBENT WATERPROOF MATERIALS NOT LESS THAN 6 FEET |
| | ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES |
| | ABOVE THE DRAIN OF THE SHOWER. |
| | ***D) FBC PL 421.4.1 AND 421.5: FLOOR SURFACES SHALL BE |
| | CONSTRUCTED OF IMPERVIOUS, NONCORROSIVE, NONABSORBENT |
| | AND WATERPROOF MATERIALS |
| | ***E) NEW COMMENT: REGARDING THE LINER EXTENDING INTO |
| | THE BATHROOM FLOOR, PER WPB FBC 107.2.1, PROVIDE |
| | DETAIL/DIRECTION FOR SHEET APPLIED OR TROWEL APPLIED |
| | METHODS TO PREVENT WATER FROM MIGRATING BACK TO THE |
| | SHOWER DRAIN PIPE FLOOR PENETRATION. |
| | |
| | |
| | END OF COMMENTS. |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED |
| | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER PX928 |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | MOBILE 561-246-0882 |
| | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND |
| | THURSDAYS |
| | |
| | 22021014 2427 PRESIDENTIAL WAY # 404 |
| | |