| Date |
Text |
| 2022-04-07 14:44:10 | BUILDING ALTERATION |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) A SEPARATE PERMIT IS REQUIRED FOR BUILDING |
| | DEMOLITION. |
| | |
| | 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE |
| | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS |
| | AND ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE |
| | REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER |
| | OF RECORD FBC WPB 107.3.4 |
| | |
| | 3) PLEASE SHOW THAT DOOR (01) DOES NOT BLOCK EGRESS - |
| | FBC 1005.7.1 DOORS. |
| | DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED |
| | WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY |
| | POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE |
| | THAN ONE-HALF. |
| | |
| | 4) PLEASE SHOW WALLS AT TOILETS AND MOP SINKS TO COMPLY |
| | WITH FBC 1210.2.2 WALLS AND PARTITIONS. |
| | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT |
| | CONSIDERED A HARD SURFACE) |
| | |
| | 5) PLEASE SHOW ACCESSIBLE ENTRY DOOR MANEUVERING SPACE |
| | (18" BESIDE THE DOOR LATCH) TO COMPLY WITH FBC A |
| | 404.2.4 |
| | |
| | 6) ACCESSIBLE RESTROOM - PLEASE USE THE WORDS |
| | "REFLECTIVE SURFACE" TO DESCRIBE THE MAX. HEIGHT OF THE |
| | MIRROR FROM THE FLOOR - FBC A 603.3 MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 7) BUILDING PERMIT APPLICATION - DESCRIPTION OF WOK |
| | SAYS "RETAIL FIT OUT" - DRAWINGS SHOW BUILDING AS |
| | OCCUPANCY CLASSIFICATION S1 - PLEASE CLEARIFY (UPDATE |
| | THE BUILDING PERMIT APPLICATION TO REFLECT THE SCOPE OF |
| | WORK) |
| | |
| | |
| | |