Plan Review Notes
Plan Review Notes For Permit 22020933
Permit Number 22020933
Review Stop B
Sequence Number 2
Notes
Date Text
2022-05-02 16:39:51BUILD OUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE DIAGONAL MEASUREMENT OF THE UNIT AND
 THE EXIT DOOR SEPARATION DISTANCE - FBC 1007.1.1TWO
 EXITS OR EXIT ACCESS DOORWAYS.
 WHERE TWO EXITS, EXIT ACCESS DOORWAYS, EXIT ACCESS
 STAIRWAYS OR RAMPS, OR ANY COMBINATION THEREOF, ARE
 REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THEY
 SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN
 ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL
 DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED
 IN A STRAIGHT LINE BETWEEN THEM.