| Plan Review Notes For Permit 22020933 |
| Permit Number |
22020933 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-04-14 16:17:56 | BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE WALLS SURROUNDING THE MOP SINK TO | | | COMPLY WITH FBC 1210.2.2 WALLS AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT | | | CONSIDERED A HARD SURFACE) | | | | | | 2) PLEASE SHOW THE DIAGONAL MEASUREMENT OF THE UNIT AND | | | THE EXIT DOOR SEPARATION DISTANCE - FBC 1007.1.1TWO | | | EXITS OR EXIT ACCESS DOORWAYS. | | | WHERE TWO EXITS, EXIT ACCESS DOORWAYS, EXIT ACCESS | | | STAIRWAYS OR RAMPS, OR ANY COMBINATION THEREOF, ARE | | | REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THEY | | | SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN | | | ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL | | | DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED | | | IN A STRAIGHT LINE BETWEEN THEM. |
|