| Date |
Text |
| 2022-02-12 12:18:39 | 2ND REVIEW FBC-2020 RES. GAS |
| | PERMIT- 22020184 |
| | 2/12/2022 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | PLEASE ADDRESS PREVIOUS PLANS EXAMINERS COMMENTS. |
| | |
| | 1) THIS APPEARS TO BE A NEW INSTALLATION OF A GAS-FIRED |
| | TANKLESS WATER HEATER AND NOT A REPLACEMENT. WPB |
| | BUILDING DEPT. RECORDS TO NOT SHOW A PREVIOUS GAS |
| | PERMIT WAS ISSUED FOR A TANKLESS WATER HEATER. PLEASE |
| | PROVIDE A COMPLETE GAS RISER DRAWING THAT INCLUDES ALL |
| | NEW AND EXISTING GAS PIPING AND APPLIANCES AT THE |
| | RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. REFER TO |
| | FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL INDICATE: |
| | A) TYPE OF GAS- NATURAL OR LP. |
| | B) DELIVERY PRESSURE AT THE METER. |
| | C) TOTAL BTU LOAD AND BTU LOAD OF THE WATER HEATER AND |
| | OTHER EXISTING APPLIANCES. |
| | D) TYPE AND SIZE OF PIPING SUPPLYING THE WATER HEATER. |
| | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER |
| | TO THE MOST REMOTE APPLIANCE OUTLET. |
| | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. |
| | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE |
| | UNIONS. |
| | H) OUTLET PRESSURES AT REGULATORS. |
| | I) PIPE SIZING TABLES. |
| | |
| | 2) PROVIDE A DRAWING THAT SHOWS THE LOCATION OF THE |
| | WATER HEATER AND REQUIRED CLEARANCES PER MANUFACTURER'S |
| | SPECIFICATIONS AND SECS. G2427.8 & G2448.1 FBC RES |
| | |
| | 3) IF AN ELECTRICAL OUTLET HAS TO BE INSTALLED FOR THE |
| | NEW TANKLESS WATER HEATER, AND ELECTRICAL PERMIT IS |
| | REQUIRED FOR THIS NEW ELECTRICAL WORK. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | ATELYO BELISLE |
| | PLUMBING INSPECTOR / |
| | PLUMBING PLAN REVIEW |
| | AVAILABLE FROM 1:00 PM TO 4:00 PM |
| | [email protected] |
| | 561-805-6695 |
| | |
| | |
| | |
| | |