Plan Review Notes
Plan Review Notes For Permit 22020180
Permit Number 22020180
Review Stop B
Sequence Number 1
Notes
Date Text
2022-03-04 10:31:54JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL25621-R1 HAS BEEN REVISED TO FL25621-R2.
 PLEASE PROVIDE A COMPLETE SET OF PRODUCT APPROVALS.
 INCLUDE COVER PAGE, EVALUATION REPORTS AND INSTALLATION
 INSTRUCTIONS FOR SYSTEM USED. ALL APPLICABLE DETAILS
 AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE
 PRODUCT APPROVAL DRAWINGS.
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL25621.01-R1 IS NOT RATED FOR USE IN ZONE 2 &
 3 FOR STRUCTURES LOCATED IN EXPOSURE B, C, OR D WITH
 FLAT ROOF LESS THAN 7 DEGREES, HIP ROOF WITH MAX SLOPE
 OF 12:12 OR GABLE ROOF WITH SLOPE BETWEEN 4.4:12 &
 12:12 12:12 WITH A MEAN ROOF HEIGHT 30 FEET OR LESS
 WIND SPEED 170 MPH. PROVIDE SIGNED AND SEALED
 ENGINEERING FOR USE OR SELECT A SYSTEM THAT MEETS THE
 ABOVE CRITERIA. PROJECT LOCATED IN EXPOSURE C CATEGORY
 AREA.
 3. PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT
 APPROVALS/NOA'S FOR THE PROPOSED FLAT ROOF SYSTEM TO BE
 USED. INCLUDE COVER PAGE, EVALUATION REPORTS AND
 INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 4. SUBMITTED MIAMI-DADE COUNTY NOA 21-0602.14 COVERS
 MULTIPLE PRODUCTS & INSTALLATION PROCEDURES: SYSTEMS
 TYPE E(1) THROUGH E(3). SELECT PRODUCT & SYSTEM TYPE TO
 BE USED. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE
 CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 5. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND SHOW THE AREAS TO RECEIVE NEW
 ROOFING CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF
 SLOPE(S), MEAN ROOF HEIGHT(S). LOW SLOPE ROOFS MUST
 SHOW POSITIVE DRAINAGE.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  