| 2022-05-17 11:26:42 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #22020132 |
| | |
| | NOTE: |
| | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER |
| | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID |
| | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR |
| | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME |
| | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT |
| | ISSUANCE. |
| | |
| | ***IMPORTANT*** |
| | ENERGY CALCULATIONS NEED TO BE SUBMITTED AND CERTIFIED |
| | BY THE OWNER OR AUTHORIZED AGENT BEFORE ISSUING THE |
| | PERMIT. |
| | |
| | ORIGINAL COMMENT: |
| | 1- ROOF SHEATHING NAILING SPACING SPECIFIED ON SHEET |
| | S-2 DOESN'T COMPLY WITH TABLE R803.2.3.1 |
| | FBC-RESIDENTIAL. REVISE AS REQUIRED. |
| | |
| | RESPONSE: |
| | REVISED ROOF SHEATHING NAILING SPECIFICATIONS IS |
| | MISSING SPECIFICATIONS FOR ROOF ZONE 2N. |
| | |
| | 2- OK. |
| | 3- OK. |
| | |
| | ORIGINAL COMMENT: |
| | 4-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | R101.5 FBC-ENERGY CONSERVATION. |
| | NOTE: PLEASE MAKE SURE FORM IS PROPERLY SIGNED BY ALL |
| | REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID |
| | CONFLICTS/DELAYS. |
| | |
| | RESPONSE: |
| | A)ENERGY CALCULATIONS FORM R405-2020 IS REQUIRED TO BE |
| | CERTIFIED AT THE BOTTOM BY THE OWNER, THE OWNER'S |
| | ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY |
| | THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY |
| | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | B)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE |
| | LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY |
| | CONSERVATION. |
| | |
| | ORIGINAL COMMENT: |
| | 5- PRODUCT APPROVALS |
| | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 |
| | FOR: |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW |
| | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL |
| | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL): |
| | |
| | A)SINGLE HUNG WINDOWS. |
| | B)ENTRY DOOR. |
| | C)GREAT ROOM SWING DOOR. |
| | D)ROOF SHINGLES. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. CONTRACTOR TO RESPOND IF |
| | SUBMITTING LATER AS A DEFERRED SUBMITTAL OR IF |
| | SUBMITTING THEM AT RESUBMITAL. |
| | |
| | 6- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS |
| | NOTE: COORDINATE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT |
| | ON SHEET A-1 WITH PRODUCT APPROVALS SUBMITTED TO AVOID |
| | CONFLICTS/DELAYS. |
| | |
| | ORIGINAL COMMENT: |
| | 7- DRAINAGE PLAN DRAWING C-1: REVISE PROPOSED DRAINAGE |
| | AT THE REAR AND RIGHT HAND SIDE OF THE PROPERTY. |
| | SURFACE DRAINAGE CAN NOT BE DIVERTED TO ADJACENT |
| | PROPERTIES. DRAINAGE WATER TO BE KEPT WITHIN THE LOT OR |
| | DIVERTED TOWARDS THE STREET. R401.3 FBC-RESIDENTIAL. |
| | SEC. 107.2.5 CITY AMENDMENTS AND SEC. 110.9 CITY |
| | AMENDMENTS. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. DRAINAGE PLAN WAS NOT |
| | REVISED. CONTRACTOR TO RESPOND IF SUBMITTING LATER AS A |
| | DEFERRED SUBMITAL OR IF SUBMITTING REVISED DRAINAGE |
| | PLAN AT RESUBMITAL. |
| | |
| | 8- OK. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE |
| | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |