| 2022-08-01 14:52:07 | ADD RESTROOMS |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) APPEARS TO BE A CHANGE OF OCCUPANCY - PLEASE PROVIDE |
| | A LIFE SAFETY PLAN SHOWING THE OCCUPANT LOAD, EGRESS |
| | TRAVEL DISTANCE AND WIDTH OF EXIT DOORS. FBC WPB |
| | 107.3.5.1.1 |
| | |
| | 2) PLEASE SHOW THE UNIT DIMENSIONS, SQUARE FOOTAGE. FBC |
| | WPB 107.2 |
| | |
| | 3) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS |
| | "REFLECTIVE SURFACE" WHEN REFERRING TO THE DISTANCE |
| | FROM THE FLOOR TO THE BOTTOM OF THE MIRROR - FBC A |
| | 603.3 MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 4) ACCESSIBLE RESTROOM = PLEASE SHOW THE TOILET AND |
| | SHOWER GRAB BAR HEIGHT TO THE TOP OF THE GRIPPING |
| | SURFACE - FBC A 609.4 POSITION OF GRAB BARS. |
| | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| | 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| | THE GRIPPING SURFACE |
| | |
| | 5) ACCESSIBLE RESTROOM = PLEASE SHOW THE DIMENSION FOR |
| | THE TOILET PAPER HOLDER FROM THE FACE OF THE TOILET TO |
| | THE "CENTER" OF THE TOILET DISPENSER. FBC A 604.7 |
| | DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. |
| | |
| | 6) ACCESSIBLE RESTROOM = PLEASE SHOW THE SHOWER AREA TO |
| | COMPLY WITH FBC A 608.1 GENERAL. |
| | SHOWER COMPARTMENTS SHALL COMPLY WITH 608. |