| Date |
Text |
| 2022-04-05 13:28:26 | ADD RESTROOMS |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE PROVIDE WALL FRAMING DETAILS - FBC WPB |
| | 107.2.1 |
| | |
| | 2) PLEASE SHOW WALL FINISHES TO COMPLY WITH FBC |
| | 1210.2.2 WALLS AND PARTITIONS. |
| | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| | THAN 4 FEET (1219 MM) ABOVE THE FLOOR - (DRYWALL IS NOT |
| | CONSIDERED A HARD SURFACE) |
| | |
| | 3) PLEASE SHOW BASE BOARDS TO COMPLY WITH FBC 1210.2.1 |
| | FLOORS AND WALL BASES. |
| | IN OTHER THAN DWELLING UNITS, TOILET, BATHING AND |
| | SHOWER ROOM FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH, |
| | HARD, NONABSORBENT SURFACE. THE INTERSECTIONS OF SUCH |
| | FLOORS WITH WALLS SHALL HAVE A SMOOTH, HARD, |
| | NONABSORBENT VERTICAL BASE THAT EXTENDS UPWARD ONTO THE |
| | WALLS NOT LESS THAN 4 INCHES (102 MM). |
| | |
| | 4) DRAWING (A 101) SHOWS A DRAWING INDEX WITH (A 102, A |
| | 103) THESE DRAWINGS ARE NOT PROVIDED. |
| | |
| | 5) PLEASE SHOW THE BUILDING CONSTRUCTION TYPE PER FBC |
| | CHAPTER 6 |
| | |
| | 6) PLEASE SHOW THE OCCUPANCY CLASSIFICATION PER FBC |
| | CHAPTER 3 |
| | |
| | 7) DRAWINGS NEED TO BE SIGNED BY THE DESIGNER - FBC WPB |
| | 107.2.1 |
| | |
| | 8) PLEASE SHOW THE ACCESSIBLE RESTROOM DETAILS AND |
| | DIMENSIONS (GRAB BAR HEIGHTS, GRAB BAR LOCATIONS, |
| | TOILET PAPER HOLDER LOCATIONS, MIRROR HEIGHT TO THE |
| | "REFLECTIVE SURFACE", FIXTURE FLOOR SPACE, DOOR SIZES) |
| | TO COMPLY WITH FBC ACCESSIBILITY |