| Date |
Text |
| 2022-05-09 11:28:01 | PLAN REVIEW BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | BU1635 BN4338 |
| | ASFPM CFM US-21-11935 |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | NFPA 70 2017 EDITION NEC 2017 |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. SUBMIT A CONSTRUCTION DRAWING ELEVATION CERTIFICATE. |
| | SEE NFIP REVIEW COMMENTS. |
| | |
| | 2. NOTE ON PLAN PAGE A-6.1 & A-6.2 STATES T.O. SLAB |
| | SHALL BE BFE + 1 FOOT. |
| | THE T.O. SLAB (DESIGN FLOOD ELEVATION) SHALL BE BFE + 2 |
| | FEET PER CITY ORDINANCE. |
| | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING |
| | CODE, RESIDENTIAL. |
| | R322.2.1 ELEVATION REQUIREMENTS. |
| | 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT |
| | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST |
| | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION |
| | PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER |
| | IS HIGHER. |
| | |
| | 3. PROVIDE THE FLORIDA PRODUCT APPROVALS AND ICC-ES |
| | REPORT FOR PROPOSED SMART VENTS. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | NOTICE: A PRINT HOLD HAS BEEN APPLIED PENDING APPROVAL |
| | OF THE CONSTRUCTION DRAWING EC. |
| | A C/O HOLD HAS BEEN APPLIED PENDING APPROVAL OF THE |
| | FINISHED CONSTRCTION EC. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |