| Date |
Text |
| 2022-03-10 11:07:40 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1) PLEASE PROVIDE THE OCCUPANCY CLASSIFICATION AND |
| | PROPSED OCCUPANCY LOAD OF THAT OCCUPANCY PER THE |
| | FLORIDA FIRE PREVENTION CODE. |
| | |
| | EXIT DOOR HARDWARE/REQUIREMENTS CAN BE DIFFERENT BASED |
| | ON THE OCCUPANCY/OCCUPANCY LOAD. |
| | |
| | |
| | 2) EXIT DOOR HARDWARE IS NOT PROVIDED THAT ENSURES |
| | COMPLIANCE WITH THE LIFE SAFETY CODE, NFPA 101 CH 7, |
| | MEANS OF EGRESS |
| | |
| | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES. |
| | |
| | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED |
| | READILY FROM THE |
| | EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. |
| | |
| | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE |
| | OF A KEY, A TOOL, |
| | OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE |
| | EGRESS SIDE. |
| | |
| | 7.2.1.5.4 THE REQUIREMENTS OF 7.2.1.5.1 AND 7.2.1.5.3 |
| | SHALL NOT APPLY |
| | WHERE OTHERWISE PROVIDED IN CHAPTERS 18 THROUGH 23. |
| | |
| | 7.2.1.5.10* A LATCH OR OTHER FASTENING DEVICE ON A DOOR |
| | LEAF SHALL BE |
| | PROVIDED WITH A RELEASING DEVICE THAT HAS AN OBVIOUS |
| | METHOD OF OPERATION |
| | AND THAT IS READILY OPERATED UNDER ALL LIGHTING |
| | CONDITIONS. |
| | |
| | 7.2.1.5.10.1 THE RELEASING MECHANISM FOR ANY LATCH |
| | SHALL BE LOCATED AS |
| | FOLLOWS: |
| | (1) NOT LESS THAN 34 IN. (865 MM) ABOVE THE FINISHED |
| | FLOOR FOR OTHER |
| | THAN EXISTING INSTALLATIONS |
| | (2) NOT MORE THAN 48 IN. (1220 MM) ABOVE THE FINISHED |
| | FLOOR |
| | 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN THE |
| | DOOR LEAF WITH NOT |
| | MORE THAN ONE RELEASING OPERATION, UNLESS OTHERWISE |
| | SPECIFIED IN |
| | 7.2.1.5.10.3, 7.2.1.5.10.4, 7.2.1.5.10.6, OR |
| | 7.2.1.5.10.7. |
| | |
| | PLEASE REVIEW AND PROVIDE DETAILS OF COMPLIANCE. |
| | |
| | |
| | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET |
| | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE |
| | ABOVE. |
| | |
| | |
| | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE |
| | RE-SUBMITTAL OF THE ABOVE. |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |
| | |