| | FINISHED CONSTRUCTION ELEVATION CERTIFICATE |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD |
| | HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS |
| | SITE IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6.0 |
| | NAVD. THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE |
| | NO. 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF |
| | FREEBOARD. THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT |
| | OR ABOVE 8.0 NAVD. |
| | |
| | 1. THE GARAGE DOOR VENT LETTER SUBMITTED FOR REVIEW BY |
| | SCPOTT HAMITON, P.E. REFERENCES NOA 20-0922.19 FOR THE |
| | OHD'S. THIS NOA CANNOT BE LOCATED UNDER MASTER PERMIT |
| | 19080773. SUBMIT NOA 20-0922.19 FOR REVIEW. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | 2. THE GARAGE FLOOD VENT LETTER SUBMITTED FOR REVIEW BY |
| | ROGER PATTERSON JANSSEN, P,E, IS TO RE-INSTALL THE |
| | FLOOD VENTS TO COMPLY WITH THE REQUIREMENTS OF FEMA'S |
| | NFIP TECHNICAL BULLETIN 1. SEE REVISED PLAN PAGE A-1.01 |
| | SUBMITTED FOR REVIEW. 2 FLOOD VENTS, MODEL 1540-574, |
| | SHALL BE INSTALLED IN OHD #102 AND A STACKER VENT, |
| | MODEL 1540-521 WILL BE INSTALLED ON THE SOUTHWEST |
| | CORNER OF THE GARAGE. |
| | PROVIDE THE PRODUCT APPROVALS, FL5822-R7, FOR MODELS |
| | 1540-574 AND 1540-521. INCLUDE THE COVER SHEET, |
| | EVALUATION REPORT AND INSTALLATION INSTRUCTIONS. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | PLEASE REFERENCE THE ELEVATION CERTIFICATE FOR THE |
| | FOLLWING COMMENTS: |
| | |
| | 3. A6. PHOTOGRAPHS. THE CERTIFIER MUST PROVIDE AT LEAST |
| | 2 PHOTOGRAPHS SHOWING THE FRONT AND REAR OF THE |
| | BUILDING TAKEN WITHIN 90 DAYS FROM THE DATE OF |
| | CERTIFICATION. PROVIDE A PHOTOGRAPH OF THE FOUNDATION |
| | SHOWING A REPRESENTATIVE EXAMPLE OF THE FLOOD OPENINGS |
| | OR VENTS. |
| | FEMA EC INSTRUCTIONS PAGE 1 OF 9. |
| | |
| | 4. A7. THE BUILDING DIAGRAM NUMBER IS STATED AS 1B. |
| | BASED ON THE FOUNDATION OF THE PROPOSED STRUCTURE, THE |
| | BUILDING DIAGRAM NUMBER SHOULD BE 1A. |
| | FEMA EC INSTRUCTIONS, PAGE 1 OF 9. |
| | |
| | 5. A9 B). THE NUMBER OF FLOOD OPENINGS IS STATED AS 4. |
| | THERE ARE ONLY 3 FLOOD OPENINGS (1 ON THE SW CORNWER OF |
| | THE BUILDING AND 2 IN OHD #102. |
| | FEMA EC INSTRUCTIONS, PAGE 2 OF 9. |
| | |
| | 6. SECTION D - COMMENTS. ITEM #3 REFERENCES FLOOD VENT |
| | MODEL: SMART VENT 1540-520. THIS MODEL IS NOT USED FOR |
| | THIS PROJECT, IT SHOULD STATE: MODELS 1540-521 AND |
| | 1540-574. |
| | PROVIDE THE REFERENCED ICC-ES REPORT FOR THE SMART |
| | VENTS. |
| | PROVIDE THE TOP OF SLAB ELEVATION FOR THE FUTURE |
| | GENERATOR SHOWN ON SITE PLAN SP-1.01, UNDER MASTER |
| | PERMIT 19080773. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | |
| | |