| 2022-03-15 17:55:27 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE POOL DEPTH IS SPECIFIED AS MORE THAN 5 FEET | | | WHICH REQUIRES A LADDER, STEPS, BENCH OR SWIMOUT IN THE | | | DEEP END. R4501.18 LADDERS AND STEPS. ALL POOLS WHETHER | | | PUBLIC OR PRIVATE SHALL BE PROVIDED WITH A LADDER OR | | | STEPS IN THE SHALLOW END WHERE WATER DEPTH EXCEEDS 24 | | | INCHES (610 MM). IN PRIVATE POOLS WHERE WATER DEPTH | | | EXCEEDS 5 FEET (1524 MM), THERE SHALL BE LADDERS, | | | STAIRS OR UNDERWATER BENCHES/SWIMOUTS IN THE DEEP END. | | | WHERE MANUFACTURED DIVING EQUIPMENT IS TO BE USED, | | | BENCHES OR SWIMOUTS SHALL BE RECESSED OR LOCATED IN A | | | CORNER. | | | EXCEPTION: IN PRIVATE POOLS HAVING MORE THAN ONE | | | SHALLOW END, ONLY ONE SET OF STEPS ARE REQUIRED. A | | | BENCH, SWIM-OUT OR LADDER MAY BE USED AT ALL ADDITIONAL | | | SHALLOW ENDS IN LIEU OF AN ADDITIONAL SET OF STEPS. |
|