| Date |
Text |
| 2022-02-16 08:26:23 | OFFICE BUILDOUT |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE |
| | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| | PRODUCT APPROVALS FOR THE EXTERIOR DOORS - ALL PRODUCT |
| | APPROVALS NEED TO BE REVIEWED AND MARKED APPROVED BY |
| | THE DESIGNER OF RECORD FBC WPB 107.3.4 |
| | |
| | 2) PLEASE SHOW THE WIND DESIGN CRITERIA USED FOR THE |
| | WIND DESIGN FBC 1603.1.4 |
| | |
| | 3) PLEASE SHOW THE REQUIRED EXTERIOR COMPONET (DOOR |
| | OPENING) WIND DESIGN PRESSURES FBC 1609.1 |
| | |
| | 4) PLEASE SHOW THE RESTROOM WALL AND MOP SINK WALL |
| | FINISH PER FBC 1210.2.2 WALLS AND PARTITIONS. |
| | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR |
| | STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS |
| | SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY |
| | MOISTURE. |
| | |
| | 5) PLEASE SHOW RESTROOM FLOOR AND BASE BOARD PER FBC |
| | 1210.2.1FLOORS AND WALL BASES. |
| | IN OTHER THAN DWELLING UNITS, TOILET, BATHING AND |
| | SHOWER ROOM FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH, |
| | HARD, NONABSORBENT SURFACE. THE INTERSECTIONS OF SUCH |
| | FLOORS WITH WALLS SHALL HAVE A SMOOTH, HARD, |
| | NONABSORBENT VERTICAL BASE THAT EXTENDS UPWARD ONTO THE |
| | WALLS NOT LESS THAN 4 INCHES (102 MM). |
| | |
| | 6) ACCESSIBLE RESTROOM - YOU SHOW 44" TO THE BOTTOM OF |
| | THE MIRROR - SHOULD BE 40" TO THE BOTTOM OF THE |
| | "REFLECTIVE SURFACE" - PLEASE SHOW MIRROR HEIGHT FROM |
| | THE FINISHED FLOOR TO THE BOTTOM OF THE "REFLECTIVE |
| | SURFACE" PER FBC 603.3 MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |