| Date |
Text |
| 2022-02-23 07:33:46 | ****CORRECTIONS**** |
| | |
| | PLAN |
| | REVIEW COMMENTS |
| | |
| | 3RD REVIEW: FBC SEVENTH EDITION (2020) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | BRIGHT BIKE DOCKING STATIONS (MASTER) PLAN REVIEW. |
| | 501 EVERNIA ST. |
| | 3RD REVIEW |
| | STATUS: DENIED |
| | |
| | BUILDING/STRUCTURAL REVIEW COMMENTS: |
| | 1) RESOLVED. |
| | 2) RESOLVED. |
| | 3) RESOLVED. |
| | 4) RESOLVED. |
| | 5) [NOT ADDRESSED. THIS IS STILL AN ISSUE WHEN THE |
| | INSTALLATION IS ON PAVERS OR ASPHALT.] THERE IS A NOTE |
| | ON PAGE 2 OF THE CALCULATIONS FOR THE PAVER CALULATIONS |
| | WHICH STATES THE CALCULATIONS ARE FOR THE DECO BIKE |
| | DOCK STANDS TO RESIST HURRICANE WIND LOADS AND ALL |
| | OTHER ITEMS, BIKES, KIOSK WILL BE REMOVED IN THE EVENT |
| | OF A HURRICANE. A STORM PREPARATION PLAN WILL BE |
| | REQUIRED WHICH SPECIFIES THE ITEMS THAT WILL BE |
| | REMOVED, WHEN THE ITEMS WILL BE REMOVED (AT WHICH TIME |
| | PRIOR TO THE WIND EVENT), WHO WILL BE RESPONSIBLE FOR |
| | REMOVING THEM (PROVIDE CONTACT INFORMATION) AND WHERE |
| | THEY WILL BE STORED. FBC AMENDMENTS 107.2.1 |
| | 6) INFORMATIONAL - SEPARATE PERMITS ALONG WITH A |
| | SURVEY/SITE PLAN WILL BE REQUIRED FOR EACH LOCATION. |
| | FBC AMENDMENTS 107.2.5 |
| | 7) THE PROPOSED ANCHORING METHOD FOR THE EQUIPMENT IS |
| | TO BE PROVIDED WITH EACH SEPARATE APPLICATION DEPENDING |
| | ON THE TYPE OF BASE SUBSTRATE AT THAT LOCATION. FBC |
| | AMENDMENTS 107.2.1 |
| | 8) RESOLVED. A 6" THICK CONCRETE SLAB IS REQUIRED IN |
| | EXPOSURE D LOCATIONS. |
| | 9) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH |
| | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. |
| | |
| | 10) NEW COMMENTS: IT APPEARS THAT THERE ARE SOME ISSUES |
| | WITH THE BRIGHTBIKE SITE PREPARATION LIST. |
| | - #4 DOCKS ARE TO BE INSTALLED ON ASPHALT (SAME INSTALL |
| | AS PAVERS) AND THERE IS AN N IN THE STEEL PLATES NEEDED |
| | COLUMN. THE PLATES ARE REQUIRED. |
| | - #8 DOCKS ARE TO BE INSTALLED ON 4" CONCRETE SLAB. |
| | THIS IS AN EXPOSURE D LOCATION. THE ENGINEERING |
| | REQUIRES 6" SLABS IN EXPOSURE D. |
| | - #9 DOCK INSTALLATION INFORMATION IS BLANK. THIS IS |
| | EXPOSURE D AND WILL REQUIRE A 6" SLAB. |
| | - #13 DOCKS ARE TO BE INSTALLED ON 4" CONCRETE SLAB. |
| | THIS IS AN EXPOSURE D LOCATION. THE ENGINEERING |
| | REQUIRES 6" SLABS IN EXPOSURE D. |
| | - #15 THE FINAL SURFACE INFORMATION IS BLANK. |
| | |
| | INFO ONLY - THIS WILL BE INSTALLED AT THE FOLLOWING |
| | LOCATIONS: |
| | |
| | STATION 1 - 22010670 |
| | STATION 2 - 22010671 |
| | STATION 3 - 22010672 |
| | STATION 4 - 22010673 |
| | STATION 5 - 22010674 |
| | STATION 6 - 22010676 |
| | STATION 7 - 22010677 |
| | STATION 8 - 22010678 |
| | STATION 9 - 22010680 |
| | STATION 11 - 22010681 |
| | STATION 12 - 22010683 |
| | STATION 13 - 220100685 |
| | STATION 14 - 22010686 |
| | STATION 16 - 22010687 |
| | STATION 17 - 22010688 |
| | STATION 19 - 22010689 |
| | |
| | |