| | 22010396 8225 IBIS BLVD |
| | |
| | 2ND REVIEW |
| | PLUMBING COMMENTS: DENIED |
| | ORIGINAL COMMENTS: |
| | 1.AD101 DEMO FLOOR PLAN KEY NOTE D5 REFERS TO PLUMBING |
| | PLANS FOR TERMINATION OF WATER SUPPLY LINES AND |
| | DRAINPIPES; G1002 DRAWING INDEX LISTS P001 AND P002 |
| | PLUMBING DRAWINGS. THERE HAVE BEEN NO PLUMBING DRAWINGS |
| | SUBMITTED. PER WPB FBC 107.2.1 PROVIDE PLUMBING |
| | DRAWINGS WITH CLEAR DIRECTION FOR TERMINATION OF SAID |
| | PIPES. |
| | COMPLIED |
| | |
| | 2.PER WPB FBC 107.2.1, RECONCILE SUBMITTED DRAWINGS AND |
| | G1002 DRAWING INDEX. |
| | COMPLIED |
| | |
| | NEW COMMENTS: |
| | 1.P-001/SLAB REPAIR DETAIL: PER WPB FBC 107.2.1, |
| | PROVIDE A NOTE "THE REPAIR SHALL ALSO INCLUDE TERMITE |
| | TREATMENT OF THE SOIL. A COPY OF THE TERMITE |
| | CERTIFICATE SHALL BE ONSITE FOR THE FINAL INSPECTION." |
| | |
| | 2.P-0.01/PLUMBING SPECIFICATIONS; 2.01; PER FBC PL |
| | TABLE 605.4, SCHEDULE 40 PVC IS NOT APPROVED FOR |
| | DOMESTIC WATER DISTRIBUTION. |
| | |
| | 3.ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL BE |
| | LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND 605.2.1. |
| | PER WPB FBC 107.2.1, PROVIDE NOTE ON THE PLANS STATING |
| | THE SAME. |
| | |
| | 4.PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL WITH |
| | A NOTE STATING "HORIZONTAL PIPE SHALL BE SUPPORTED IN |
| | ACCORDANCE WITH FBC PL TABLE 308.5". |
| | |
| | 5.P-0.01/PLUMBING FIXTURE SCHEDULE/LENOX XL PEDICURE |
| | CHAIR: PER WPB FBC 107.2.1, PROVIDE THE FOLLOWING: |
| | ***A) MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL |
| | AND PLUMBING/ELECTRICAL ROUGH-IN SHEET. |
| | ***B) CERTIFICATE OF COMPLIANCE CERTIFYING FACTORY |
| | INSTALLATION OF DUAL CHECK VALVE BACKFLOW PREVENTER, |
| | TESTED AND CERTIFIED TO MEET NSF 61 AND ASSE 1024, CSA |
| | B64.6 (SEE FBC PL 605.3 AND TABLE 608.1) ONE (1) EACH |
| | REQUIRED FOR HOT AND COLD WATER CONNECTIONS. |
| | ***C) IN LIEU OF PROVIDING CERTIFICATE OF COMPLIANCE |
| | WITH CORRECT STANDARDS, SPECIFY DEVICE FOR INSTALLATION |
| | BY PLUMBER. ONE (1) EACH REQUIRED FOR HOT AND COLD |
| | WATER CONNECTIONS. |
| | ***D) LIST ALL APPLICABLE OPTIONS. |
| | |
| | 6.P-1.01/SANITARY ISOMETRIC: PER FBC PL TABLES 709.1, |
| | 709.2 AND 710.1(2), THE HORIZONTAL FIXTURE BRANCH |
| | CONNECTING THE TWO FIXTURE DRAINS TO THE EXISTING 2 |
| | INCH BRANCH OF THE BUILDING DRAIN SHALL BE 2 INCH, NOT |
| | 1-1/2 INCH (TWO OCCURRENCES). |
| | |
| | END OF COMMENTS. |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED |
| | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| | |