| Date |
Text |
| 2022-06-22 15:37:34 | PLAN REVIEW BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | BU1635 BN4338 |
| | ASFPM CFM US-21-11935 |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | NFPA 70 2017 EDITION NEC 2017 |
| | |
| | 3RD REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | NOTICE: |
| | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. |
| | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED |
| | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN |
| | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER |
| | PREVIOUS COMMENTS. |
| | |
| | COMMENTS FROM 2ND REVIEW HAVE NOT BEEN ADDRESSED. (#6 |
| | HAS BEEN CORRECTED) |
| | |
| | |
| | 1. SUBMITTAL SHEETS 10 AND 11 ARE BOTH LABLED PLAN PAGE |
| | S3.0. |
| | SHEET 10 IS A FOUNDATION PLAN AND SHEET 11 IS A ROOF |
| | FRAMING PLAN. |
| | EACH PLAN PAGE SHALL BEAR A SEPERATE PAGE NUMBER. |
| | PLEASE CLARIFY |
| | PLEASE USE PROPER NAMING CONVENTION FOR PLAN PAGES. |
| | |
| | 2. DETAIL TAGS ON SUBMITTAL SHEET 014, FOUNDATION PLAN |
| | LABLED S1.0, REFERENCES PLAN PAGE S4.0. |
| | NO PLAN PAGE S4.0 HAS BEEN SUBMITTED FOR REVIEW. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | 3. DETAIL TAG ON SUBMITTAL SHEET 014, FOUNDATION PLAN |
| | LABLED S1.0, REFERENCES DETAIL 2/S2.0. |
| | DETAIL 2/S2.0 IS FOR THE 2ND FLOOR TIE-BEAM. |
| | PLEASE CLARIFY. |
| | PLEASE USE PROPER NAMING CONVENTION FOR PLAN PAGES. |
| | |
| | 4. FOUNDATION PLAN PAGE S1.0 INDICATES THIS WILL BE A |
| | SLAB ON GRADE FOUNDATION (SOG). |
| | FOUNDATION DETAILS ON PLAN PAGE S3.0 INDICATES THIS |
| | WILL BE AN ELEVATED SLAB ON STEM WALLS. |
| | PLEASE CLARIFY. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | 5. PROVIDE A ROOF DRAINAGE PLAN. (FLAT ROOF WITH |
| | PARAPETS) |
| | R903.4ROOF DRAINAGE. |
| | UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF |
| | DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE |
| | ROOF. WHERE REQUIRED FOR ROOF DRAINAGE, SCUPPERS SHALL |
| | BE PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR |
| | PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY |
| | THE ROOF SLOPE AND CONTRIBUTING ROOF AREA. |
| | |
| | 6. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | |
| | |
| | |