| Date |
Text |
| 2022-04-13 13:14:55 | POOL |
| | |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) FENCE UNDER PERMIT 22031417 INPROGRESS (OK) - ALONG |
| | WITH A FENCE - - BARRIER FROM THE HOME NEEDS TO MEET |
| | R4501.17.1.9 -- (PLEASE WRITE ON THE BARRIER DRAWING |
| | THE TYPE OF BARRIER FROM THE HOME - WINDOW AND DOOR |
| | ALARMS OR POOL ALARM) |
| | |
| | R4501.17.1.9 |
| | WHERE A WALL OF A DWELLING SERVES AS PART OF THE |
| | BARRIER, ONE OF THE FOLLOWING SHALL APPLY: |
| | |
| | 1.ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM |
| | THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT |
| | ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND |
| | PRESSURE RATING OF 85 DBA AT 10 FEET (3048 MM). ANY |
| | DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES |
| | (1372 MM) ABOVE THE THRESHOLD OF THE ACCESS. SEPARATE |
| | ALARMS ARE NOT REQUIRED FOR EACH DOOR OR WINDOW IF |
| | SENSORS WIRED TO A CENTRAL ALARM SOUND WHEN CONTACT IS |
| | BROKEN AT ANY OPENING. |
| | |
| | EXCEPTIONS: |
| | |
| | A.SCREENED OR PROTECTED WINDOWS HAVING A BOTTOM SILL |
| | HEIGHT OF 48 INCHES (1219 MM) OR MORE MEASURED FROM THE |
| | INTERIOR FINISHED FLOOR AT THE POOL ACCESS LEVEL. |
| | |
| | B.WINDOWS FACING THE POOL ON FLOOR ABOVE THE FIRST |
| | STORY. |
| | |
| | C.SCREENED OR PROTECTED PASS-THROUGH KITCHEN WINDOWS 42 |
| | INCHES (1067 MM) OR HIGHER WITH A COUNTER BENEATH. |
| | |
| | 2.ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO |
| | THE POOL MUST BE EQUIPPED WITH A SELF-CLOSING, |
| | SELF-LATCHING DEVICE WITH POSITIVE MECHANICAL |
| | LATCHING/LOCKING INSTALLED A MINIMUM OF 54 INCHES (1372 |
| | MM) ABOVE THE THRESHOLD, WHICH IS APPROVED BY THE |
| | AUTHORITY HAVING JURISDICTION. |
| | |
| | 3.A SWIMMING POOL ALARM THAT, WHEN PLACED IN A POOL, |
| | SOUNDS AN ALARM UPON DETECTION OF AN ACCIDENTAL OR |
| | UNAUTHORIZED ENTRANCE INTO THE WATER. SUCH POOL ALARM |
| | MUST MEET AND BE INDEPENDENTLY CERTIFIED TO ASTM |
| | STANDARD F2208, TITLED ?STANDARD SAFETY SPECIFICATION |
| | FOR RESIDENTIAL POOL ALARMS,? WHICH INCLUDES SURFACE |
| | MOTION, PRESSURE, SONAR, LASER, AND INFRARED ALARMS. |
| | FOR PURPOSES OF THIS PARAGRAPH, THE TERM ?SWIMMING POOL |
| | ALARM? DOES NOT INCLUDE ANY SWIMMING PROTECTION ALARM |
| | DEVICE DESIGNED FOR INDIVIDUAL USE, SUCH AS AN ALARM |
| | ATTACHED TO A CHILD THAT SOUNDS WHEN THE CHILD EXCEEDS |
| | A CERTAIN DISTANCE OR BECOMES SUBMERGED IN WATER. |