2022-03-08 09:23:08ROOFING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 2.PROVIDE DESIGN PRESSURES FOR NEW ROOFING PER FIGURE
 R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
 R301.2.1.1WIND DESIGN REQUIRED.
  
 3.PROVIDE ROOF SHEATHING FASTENER SCHEDULE PER DESIGN
 PRESSURES.
 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING
 SCHEDULE FOR WOOD STRUCTURAL PANELS.
  
 4. PROVIDE ROOF TO WALL RETROFIT PER FBC EXISTING CHPT
 7. (STRUCTURE BUILT BEFORE 1991 WITH A VALUE EXCEEDING
 $300,000)
 706.8.1ROOF-TO-WALL CONNECTIONS FOR STRUCTURES WITH
 WOOD ROOF DECKS.
  
 5.PROVIDE A ROOF DRAINAGE PLAN.
 R903.4ROOF DRAINAGE.
 UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF
 DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE
 ROOF. WHERE REQUIRED FOR ROOF DRAINAGE, SCUPPERS SHALL
 BE PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR
 PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY
 THE ROOF SLOPE AND CONTRIBUTING ROOF AREA.
 R903.4.1OVERFLOW DRAINS AND SCUPPERS.
  
 6.GUTTERS
 R903.4.2ONE AND TWO-FAMILY DWELLINGS, AND PRIVATE
 GARAGES.
 WHEN GUTTERS AND LEADERS ARE PLACED ON THE OUTSIDE OF
 BUILDINGS, THE GUTTERS AND LEADERS SHALL BE CONSTRUCTED
 OF METAL OR APPROVED PLASTIC FOR OUTDOOR EXPOSURE WITH
 LAPPED, SOLDERED OR CAULKED JOINTS AND SHALL BE
 SECURELY FASTENED TO THE BUILDING WITH A CORROSION
 RESISTANT FASTENING DEVICE OF SIMILAR OR COMPATIBLE
 MATERIAL TO THE GUTTERS AND DOWNSPOUTS.
  
 7.PER NOA 16-0628.05, LIMITATIONS NOTE #7, PROVIDE
 ENHANCED FASTENER CALCULATIONS BY A QUALIFIED DESIGN
 PROFESSIONAL.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  